{"product_id":"3500-91-01-cn-bently-nevada-high-speed-egd-interface","title":"3500\/91-01-CN Bently Nevada High-Speed EGD Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/91-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-speed data bridge between the 3500 Machinery Protection System and GE Mark VI\/VIe turbine control platforms. Utilizing the Ethernet Global Data (EGD) protocol, this module facilitates the deterministic transfer of critical vibration levels, alarm statuses, and system events. Unlike standard asynchronous gateways, the 3500\/91 ensures that time-sensitive machinery data arrives within the strict execution windows required by turbine control loops, enabling synchronized protection and control strategies.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/91-01-CN configuration designates the following:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/91:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries designation for the EGD Communication Gateway.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the EGD Communication Gateway main module type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates country-specific agency approvals (including specialized compliance for the Chinese market and international standards).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/91-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Global Data (EGD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 10\/100 Mbps RJ45 Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Update Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable (10 ms to 100 ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlarms, Channel Values, Status, Event Logs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.4 Watts (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRead-Only EGD access (Protects rack config)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +149 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.1 cm x 3.8 cm x 24.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.79 kg (1.74 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe EGD protocol eliminates the \"request-response\" latency inherent in Modbus. The 3500\/91 pushes data at configured intervals (as fast as 10ms), providing the GE Mark VIe controller with a real-time stream of machinery health data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardened Cyber Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides read-only access to the 3500 rack data. This architectural \"air-gap\" prevents external network actors from modifying critical machinery protection setpoints or configuration parameters through the Ethernet port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless GE Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned as a native companion to the GE Speedtronic™ turbine control family, the 3500\/91 simplifies the configuration of \"Consumed Data\" pages in the control system, reducing engineering hours during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe gateway transmits not just primary values, but also detailed system event logs and diagnostic statuses. This allows operators to troubleshoot module health and sensor integrity directly from the HMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt for the demanding environment of power plant control rooms, the module operates reliably up to +65 °C. The \"CN\" certification ensures the hardware meets specific regional electrical and safety requirements for critical infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Does the 3500\/91-01-CN support Modbus TCP\/IP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 3500\/91 is a dedicated EGD (Ethernet Global Data) gateway. For Modbus TCP\/IP or serial requirements, you should utilize the 3500\/92 Communications Gateway module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can I install this module in a live 3500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/91 supports hot-swapping into an energized rack. However, the system requires configuration via the 3500 Rack Configuration Software before it can begin broadcasting data to the turbine control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Is this 3500\/91-01-CN module 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the Bently Nevada 3500\/91-01-CN in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal condition. The unit ships in original factory packaging with a clean serial number and the manufacturer's quality documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. How many 3500\/91 modules can I install in a single rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA single 3500 rack typically accommodates up to two communication gateways (in slots next to the RIM) to provide redundant data paths to the control system, ensuring no single point of failure in the monitoring network.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42894953939034,"sku":"3500\/91","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/52_45ecf0f0-eecc-401d-8900-c4a423029d04.jpg?v=1770369110","url":"https:\/\/www.spareoil.com\/products\/3500-91-01-cn-bently-nevada-high-speed-egd-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}