{"product_id":"4-channel-relay-amplifier-module-hima-f3421","title":"4-Channel Relay Amplifier Module | HIMA F3421","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA F3421 (Factory Part Number: 981342102) operates as a high-integrity, 4-channel relay amplifier module engineered for HIMA HIMatrix and Planar F safety instrumented systems (SIS). This critical control component serves as an isolated intermediary between low-power logic processing circuits and heavy field equipment. It converts low-energy internal command signals into robust, high-power relay outputs with robust galvanic isolation up to 250 V. Control engineers deploy this module to drive critical safety actuators, including emergency shutdown valves, process pumps, audio-visual sirens, and interlocked fire barriers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF3421\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e981342102\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-Channel Relay Amplifier \/ Digital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA HIMatrix Platforms and Planar F Safety Frameworks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eActive Output Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 independently isolated relay amplifier channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (with standard plus\/minus 20% voltage tolerance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Amps per channel continuous driving capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVerified isolation up to 250 V between loops and logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Mechanical Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFast-acting execution timing under 10 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 2.5 Watts nominal power consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Module Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.8 cm x 12.8 cm x 2.0 cm (H x W x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kg (0.40 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Assembly Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (4.41 lbs) including protective transit packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Envelope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation Mounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirect DIN-rail compatibility or dedicated rack slot insertion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Safety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt to comply with IEC 61508 SIL 3 application loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEngineering Country of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcurement Supply Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFactory Warranty Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Months from purchase date\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eHigh-Voltage Galvanic Isolation Stops Inductive Feedback Dead\u003c\/h3\u003e\n\u003cp\u003eField-mounted inductive devices like heavy solenoid valves and magnetic motor contactors release massive reverse electromotive force (EMF) voltage spikes when they cycle off. The F3421 incorporates a robust galvanic isolation barrier rated up to 250 V between the field terminal lines and the delicate internal logic bus. This architectural block prevents raw inductive surges or stray field grounds from migrating backwards into the control network, keeping your master safety processor running without encountering memory resets or chip damage.\u003c\/p\u003e\n\u003ch3\u003eSub-10ms Mechanical Response Timing Maximizes Shutdown Speed\u003c\/h3\u003e\n\u003cp\u003eDuring an active hazard event, every millisecond of delay increases operational risk. The internal mechanical relay matrix of the F3421 features an optimized low-inertia design that moves contacts from an active energized state to a safe de-energized configuration in less than 10 milliseconds. This rapid response speed allows emergency shutdown (ESD) logic to drop isolation valves, isolate fuel lines, and trigger containment interlocks immediately, minimizing dangerous energy release in high-pressure processes.\u003c\/p\u003e\n\u003ch3\u003eLow-Mass Fanless Footprint Shrugs Off High-Vibration Enclosures\u003c\/h3\u003e\n\u003cp\u003eWeighing just 0.18 kg and housing its components in a compact 2 cm thick profile, the F3421 avoids the structural resonance issues common to bulky, heavy-gauge switching components. The thin module features solid-state board anchoring that resists continuous mechanical vibrations inside enclosures situated next to heavy pumps or compressors. Furthermore, the low-power 2.5W circuit design sheds heat naturally without requiring failure-prone cooling fans, eliminating mechanical wear points.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this specific F3421 module be hot-swapped during continuous plant operation?\u003c\/p\u003e\n\u003cp\u003eYes. If your underlying system architecture uses a redundant I\/O configuration, the hot-swappable mechanical interface allows you to remove and replace a faulty F3421 module without shutting down the master controller or interrupting adjacent running loops. Always ensure that the specific field channels are safely bypassed or stabilized before executing a hot-swap procedure on live equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the consequences if the field load exceeds the 0.5A per channel output rating?\u003c\/p\u003e\n\u003cp\u003eExceeding the continuous 0.5 Amp current threshold creates excessive localized thermal stress across the internal relay contacts, causing them to degrade prematurely or weld together in a closed position. If your field device demands higher starting or running currents, you must use the F3421 to drive an auxiliary interposing relay rated for the larger load rather than wiring the high-current device directly to the module terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do the four independent channels behave when the master 24 VDC power supply drops out?\u003c\/p\u003e\n\u003cp\u003eThe F3421 utilizes a true fail-safe de-energization design logic. If the primary 24 VDC supply fails or experiences an unrecoverable voltage drop, the internal electromagnetic coils immediately lose power, forcing all four relay contact channels to open instantly. This configuration drops the downstream field actuators into their predefined zero-energy safe positions, preventing dangerous uncommanded operation during power losses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43399417430106,"sku":"F3421","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/243._25f271cd-4e57-4378-995b-dd7f75c47597.jpg?v=1779326068","url":"https:\/\/www.spareoil.com\/products\/4-channel-relay-amplifier-module-hima-f3421","provider":"SpareOil Automation","version":"1.0","type":"link"}