{"product_id":"42110-hima-planar4-logic-module-new-original-stock","title":"42110 HIMA Planar4 Logic Module | New \u0026 Original Stock","description":"\u003ch2\u003eHIMA 42110 Planar4 Safety System Logic Function Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA 42110\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e42110\u003c\/strong\u003e Logic Function Module, operates as a dedicated hardware component for safety-critical logic processing within Planar4 safety system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e42110 (Alternate Part No: 984042110)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.31 lbs (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e3U height, 4SU width standard Planar4 rack slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e24 W (140 mA current consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eLogic Functions\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e8 independent configurable logic functions (AND, OR, NOT, XOR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eInput Channel Count\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e2 hardware input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eReaction Time\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e2-6 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eReset Time\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eFault Monitoring\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eInternal microcontroller supervision with ERR signal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eRDY (Ready) signaling for supply thresholds \u0026gt;= 20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eSafety Certification\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eSIL 4 compliant (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eRack-mounted on standard Planar4 backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFail-Safe State Execution and Safety Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA 42110\u003c\/strong\u003e executes hardwired solid-state boolean logic combinations to enforce immediate fail-safe state execution upon detection of out-of-bounds parameter boundaries. Engineered to fulfill SIL 4 safety system criteria, the module bypasses standard software operating system dependencies to prevent processor execution freezes. The internal hardware matrix continuously monitors the 2 sensor inputs through integrated microcontroller supervision. If a component fault or an input loop open-circuit occurs, the module forces its internal safety relays to de-energize, opening the diagnostic contact and driving the associated safety loops to a predictable, de-energized shutdown state.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 42110 module manage power supply dips without triggering spurious safety trips?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic block monitors the incoming 24 V DC supply line. The RDY (Ready) status indicator remains active as long as the supply voltage stays at or above 20 V DC. If the voltage drops below this 20 V DC threshold, the internal monitoring routine flags a power fault and commands the logic matrix to initiate its safe state shutdown sequence.\u003c\/p\u003e\n\u003cp\u003eQ: Can this logic module be hot-swapped within the Planar4 rack assembly while active loops are operational?\u003c\/p\u003e\n\u003cp\u003eA: No. Hot-swapping the module while the backplane bus or field loops are energized can generate inductive spikes that risk damaging the solid-state logic gates. The specific Planar4 sub-rack slot must be electrically isolated before extracting or inserting the unit to maintain system stability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSub-Rack Placement and Insertion:\u003c\/strong\u003e Slide the module into the designated 3U height, 4SU width slot of the Planar4 sub-rack. Ensure the rear Eurocard connectors align flush with the backplane receptacles before applying final seating force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Shielding:\u003c\/strong\u003e Terminate all dual-channel input sensor cables using continuous braided shielding. Ground the shield at the single entry point of the enclosure terminal assembly to prevent electromagnetic noise from causing logic processing jitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Thermal Control:\u003c\/strong\u003e Maintain vertical clearance profiles within the main enclosure to ensure ambient air temperatures around the rack remain within the 0 to +60 deg C limits. Convective airflow must not be restricted near the 24 W dissipation zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Output Wiring:\u003c\/strong\u003e Connect the ERR signal output contacts to the centralized master alarm monitoring circuit. Wire this loop using a normally closed configuration so that any internal hardware fault or power loss causes the monitoring contact to open immediately.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43415982276698,"sku":"42110","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/253.1_380c24c9-5f72-4630-aa35-05404246475f.jpg?v=1779764171","url":"https:\/\/www.spareoil.com\/products\/42110-hima-planar4-logic-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}