{"product_id":"467nhp811-dp-schneider-profibus-dp-interface-module-new-stock","title":"467NHP811-DP Schneider Profibus DP Interface Module | New Stock","description":"\u003ch2\u003eSchneider 467NHP811-DP Modicon Profibus DP Communication Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for distributed field device communication in Modicon Quantum and Premium networks, the \u003cstrong\u003eSchneider 467NHP811-DP\u003c\/strong\u003e (\u003cstrong\u003e467NHP811-DP\u003c\/strong\u003e Profibus DP Network Interface Module) provides direct physical\/electrical execution. The hardware operates as a dedicated PCMCIA card engineered to fit directly into host communication modules, including the Modicon Quantum 140CRP81100 or Premium TSXPBY100 master controllers. The module serializes backplane data registers into differential RS485 signaling variables matching the cyclic framing rules defined by the IEC 61158 Profibus standard.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e467NHP811-DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance (Manufactured in the United States options available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs) net \/ 0.291 kg (0.64 lbs) package allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.9 cm x 2.5 cm x 5.1 cm (4.3 in x 1.0 in x 2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced entirely through the master fieldbus module slot interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eProfibus DP (Master\/Slave capability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSpecialized industrial PCMCIA card adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHost modules 140CRP81100 (Quantum) \/ TSXPBY100 (Premium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rates\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eDedicated output link to standard Profibus DB9 via 490NAE91100 bus adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Node Scale\u003c\/td\u003e\n\u003ctd\u003eUp to 125 devices total across segmented lines using RS485 repeaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eBuilt-in physical isolation barriers between PLC bus and network pins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe Schneider 467NHP811-DP utilizes a specialized co-processing engine that runs independently of the main controller's central processing updates. This independence prevents varying network turnaround constraints from interrupting parameters governed under backplane bus communication velocity licenses. Transmission rates scale mathematically up to 12 Mbps, ensuring deterministic data exchange for remote peripheral drops.\u003c\/p\u003e\n\u003cp\u003eWhen bridging legacy fieldbuses over modern industrial architectures, such as Profinet \/ EtherNet\/IP deterministic networks, this PCMCIA card functions as an isolated protocol anchor. The hardware layer accommodates dense I\/O density scaling profiles up to 125 field nodes, ensuring that multi-byte variable blocks are cyclically transferred to the local rack memory maps within sub-millisecond network schedules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 467NHP811-DP card be extracted or hot-swapped from the host 140CRP81100 module under active backplane power?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal contact tracks of the PCMCIA connection system lack the specialized grounding offsets needed for live extraction. Removing or inserting the card while power is applied can cause transient current surges, risking permanent physical component failure or halting the master rack backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How is the specific network transmission rate configured on the 467NHP811-DP card assembly?\u003c\/p\u003e\n\u003cp\u003eA: The module does not feature manual hardware switches for speed selection. The transmission rate (ranging from 9.6 kbps up to 12 Mbps) is defined in the network master configuration utility within the programming software environment and downloaded directly to the module memory.\u003c\/p\u003e\n\u003cp\u003eQ: What physical adapter is required to connect standard DB9 Profibus cables to this card?\u003c\/p\u003e\n\u003cp\u003eA: The 467NHP811-DP requires a matching external connection accessory, such as the 490NAE91100 bus adapter. This adapter routes the internal PCMCIA interface ribbon out to a standard standard DB9 connector port.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShut down the primary power supply feeds to the controller chassis before attempting to insert or remove the PCMCIA communication card.\u003c\/li\u003e\n\u003cli\u003eGuide the card into the designated communication slot of the master interface module, applying steady pressure until the card is fully seated against the internal connector pins.\u003c\/li\u003e\n\u003cli\u003eAttach the required 490NAE91100 network interface adapter cable to the external port of the card and secure the structural lock mechanisms.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal nodes on the physical Profibus DP network segment have active termination resistors switched ON to prevent signal reflections.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 30 cm of space between the network cabling and adjacent high-current AC circuits or drive conductors to suppress electromagnetic signal distortion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43447707304026,"sku":"467NHP811-DP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/179_1fcf7914-1ae2-413c-abac-2f8e7446c79c.jpg?v=1780466895","url":"https:\/\/www.spareoil.com\/products\/467nhp811-dp-schneider-profibus-dp-interface-module-new-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}