{"product_id":"51404174-175-fc-qpp-0002-honeywell-safety-manager-qmr-module","title":"51404174-175 FC-QPP-0002 Honeywell Safety Manager QMR Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-QPP-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary computational engine for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. This high-integrity Quad Processor Pack (QPP) executes the core safety logic and coordinates system-wide I\/O synchronization. By utilizing a proprietary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eQuad Module Redundancy (QMR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, it delivers the extreme fault tolerance required for Safety Integrity Level (SIL) 3 environments. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing a mission-critical hardware solution for refineries, chemical plants, and offshore platforms that cannot tolerate unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-QPP-0002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eQuad Redundant (QMR) Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage (24V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Vdc (–15% to +30%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage (5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Vdc ± 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e750 mA per output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mA @ 24 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–5 °C to +70 °C (+23 °F to +158 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176 mm × 88.5 mm × 212 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, TUV, FM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuad Module Redundancy (QMR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-QPP-0002 runs four identical processing paths in parallel. This architecture performs continuous hardware-level comparisons to detect and isolate faults. If a single processing path fails, the system transitions to 3-2-0 or 2-out-of-4 voting logic, maintaining full process control without a trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Migration Path:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides a direct, pin-compatible upgrade for aging\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-QPP-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einstallations. It integrates flawlessly with legacy TPS networks and modern Experion PKS environments, allowing facilities to modernize their safety core without extensive re-wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Availability (2-out-of-4 Voting):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike traditional 1-out-of-2 or 2-out-of-3 systems, the QMR design balances safety with availability. It eliminates nuisance trips caused by transient hardware glitches while ensuring the system remains ready to respond to a genuine process demand.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Rail Power Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module handles both 24 Vdc and 5 Vdc internal supply rails. This ensures stable logic execution and robust communication across the Safety Manager backplane, even in environments with fluctuating industrial power quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Heat Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt for the rigors of industrial control rooms, the FC-QPP-0002 operates at temperatures up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+70 °C\u003c\/strong\u003e. Its precision-engineered heat dissipation allows for high-density mounting in standard safety racks without excessive thermal stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FC-QPP-0002 a direct replacement for the FC-QPP-0001?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-QPP-0002 replaces the older QPP-0001 module. It offers improved processing speed and enhanced diagnostic capabilities while maintaining the same physical form factor and backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the voting logic handle a hardware failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module uses sophisticated diagnostic hardware to \"vote\" on results. If one processor disagrees with the other three, the system identifies the faulty processor and ignores its input, allowing the plant to remain online while maintenance is scheduled.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require specific firmware versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC-QPP-0002 requires Safety Manager software compatible with Universal QPP hardware. Always verify your current system release and firmware revision before performing a hot-swap or upgrade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is \"Brand New\" condition critical for safety processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSafety processors operate in a constant state of high-speed calculation. Older or refurbished units may have degraded capacitors or micro-fractures in the PCB traces from years of thermal cycling. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit ensures the hardware meets its certified MTBF (Mean Time Between Failures), keeping your SIL 3 certification valid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870913368154,"sku":"FC-QPP-0002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/35_2a3e8224-5603-455b-a6be-717523a5dfc3.jpg?v=1776329077","url":"https:\/\/www.spareoil.com\/products\/51404174-175-fc-qpp-0002-honeywell-safety-manager-qmr-module","provider":"SpareOil Automation","version":"1.0","type":"link"}