{"product_id":"5453-754-woodward-ethernet-communication-interface","title":"5453-754 Woodward Ethernet Communication Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5453-754\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the dedicated Ethernet Field Terminal Module (FTM) for Woodward MicroNet and MicroNet Plus VME-based control platforms. This module functions as the essential hardware bridge between the internal control backplane and external plant-wide networks. It enables critical functions such as remote monitoring, high-speed data logging, and software management via Woodward’s Graphical Application Programmer (GAP). By physically separating field-side networking from the VME chassis, the 5453-754 protects sensitive control electronics from external electromagnetic interference (EMI) and transient surges.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis unit is 100% Brand New, original Woodward factory stock.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 5453-754 provides a stabilized 10Base-T interface for deterministic data exchange in turbine and engine control applications.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5453-754\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Field Terminal Module (FTM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroNet, MicroNet Plus (VME Systems)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Base-T Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP, GAP Upload\/Download\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard RJ45 Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCabling Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDouble-shielded SSTP (Recommended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 mm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 120 mm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Isolation and Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FTM architecture isolates the MicroNet CPU from external networking faults. This design ensures that electrical noise or transients originating in the plant network do not compromise the integrity of the turbine governor's core control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeaturing a standard DIN rail footprint, the 5453-754 mounts easily within the I\/O cabinet. Technicians can access the RJ45 port directly for system diagnostics without opening the primary VME chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports double-shielded Screened Shielded Twisted Pair (SSTP) cabling. This grounding capability effectively suppresses electromagnetic interference, which is a critical requirement for modules located near high-voltage motor starters or generators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative GAP Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module allows for seamless application downloads and real-time tuning through Woodward’s GAP software. It maintains high-speed data throughput to ensure that control engineers receive accurate, real-time feedback during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Protocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting Modbus TCP\/IP, the 5453-754 facilitates easy integration with third-party Distributed Control Systems (DCS) and Human-Machine Interfaces (HMI), enabling unified plant monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support Gigabit Ethernet speeds?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the 5453-754 is specifically designed for 10Base-T (10 Mbps) communication. This speed provides the necessary bandwidth for deterministic control data and GAP software interface while maintaining high signal stability in noisy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Woodward systems are compatible with the 5453-754?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FTM is compatible with Woodward MicroNet and MicroNet Plus systems that utilize VME-based CPU and communication cards. It connects via a standard interface cable to the corresponding communication card in the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre there specific cabling requirements for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To ensure peak performance and EMI rejection, we strongly recommend using double-shielded SSTP (Screened Shielded Twisted Pair) cables. Standard unshielded (UTP) cables may allow industrial noise to disrupt data packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this FTM outside of the control cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is rated for an operating temperature of 0°C to +60°C. While it can be panel-mounted or DIN rail-mounted, it should remain within an enclosure that protects it from moisture and extreme temperature fluctuations to ensure long-term hardware reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42870868803674,"sku":"5453-754","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/166.1_c38837b8-8e03-4d8b-bc96-2b1026b0b203.jpg?v=1772507699","url":"https:\/\/www.spareoil.com\/products\/5453-754-woodward-ethernet-communication-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}