{"product_id":"5501-367-woodward-micronet-series-datasheet-technical-manual","title":"5501-367 Woodward MicroNet Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eWoodward 5501-367 MicroNet Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 5501-367\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e5501-367\u003c\/strong\u003e LV Discrete FTM \/ Power Supply Interface, operates as a dedicated hardware component for signal conditioning and power distribution within MicroNet Digital Control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5501-367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard MicroNet chassis footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC (24 VDC Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e27.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e16 A (Continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Signal Support\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Isolation\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms (0-60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Profile\u003c\/td\u003e\n\u003ctd\u003eNatural Convection cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Drives and Governor Systems\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture incorporates specialized circuitry optimized for actuator loop feedback response, enabling precise governance over 0 to 200 mA analog actuator signals. The electrical topology executes high-current distribution management, handling input streams up to 27.4 A while regulating a stable continuous output of 16 A at 24 VDC to the simplex control backplane. A 1000 Vrms isolation rating (0-60 Hz) provides robust line protection against voltage surges, suppressing transient distortion and feedback ripples that might affect the speed loop stability of connected prime movers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the input and output electrical tolerances of the 5501-367 power stage?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts a nominal low-voltage DC input range of 18 to 32 VDC. Internal power conditioning circuitry converts and regulates this into a stable 24 VDC output line rated for up to 16 A continuous current delivery.\u003c\/p\u003e\n\u003cp\u003eQ: Does this specific FTM option support redundant power supply configurations?\u003c\/p\u003e\n\u003cp\u003eA: No, the 5501-367 is engineered exclusively for standard simplex (non-redundant) architectures within the MicroNet and MicroNet Plus control platforms.\u003c\/p\u003e\n\u003cp\u003eQ: How is thermal heat dissipation handled on this module when under full current loads?\u003c\/p\u003e\n\u003cp\u003eA: The module relies entirely on natural convection cooling across its chassis structure. It does not employ internal cooling fans and must be installed in environments where the ambient cabinet temperature does not exceed +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting Real Estate:\u003c\/strong\u003e Fasten the module securely into its designated chassis or FTM DIN rail orientation. Ensure all grounding spring clips seat firmly against the metal rail profile to guarantee a low-resistance path to earth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator Signal Shield Integration:\u003c\/strong\u003e Route the 0 to 200 mA actuator feedback lines using high-quality twisted, shielded cables. Terminate the shield drain wire only at the master control enclosure ground bar to eliminate common-mode ground currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Current Conductor Sizing:\u003c\/strong\u003e Select power input conductors capable of continuously supporting the maximum 27.4 A peak rating without inducing localized voltage drops or excessive wire insulation heating inside wire ducts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42870828597338,"sku":"5501-367","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/169._4e07c1d3-b6d7-45e1-8a33-a5aa3a81572f.jpg?v=1772508730","url":"https:\/\/www.spareoil.com\/products\/5501-367-woodward-micronet-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}