{"product_id":"5a-24vdc-power-supply-pw482-10-s2-yokogawa-centum","title":"5A 24VDC Power Supply PW482-10 S2 Yokogawa Centum","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa PW482-10 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance energy source for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS3000 and CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems. It converts AC input into a clean, regulated 24VDC supply to power core controllers, high-density I\/O modules, and fieldbus communication interfaces. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical infrastructure benefits from the latest S2 revision standards for enhanced safety and long-term stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePW482-10 S2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa CENTUM CS3000 \/ VP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 VAC \/ 220–240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Regulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 Amperes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports dual-redundant load sharing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage, Overcurrent, and Thermal Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevision Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS2 (Updated reliability\/safety compliance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +50 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard CENTUM Rack-mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision S2 Enhanced Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe S2 suffix designates an updated hardware revision that meets the most recent industrial reliability and safety standards. This revision optimizes heat dissipation and improves internal component longevity compared to legacy S1 or base versions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Redundant Availability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports dual-unit configurations within a single rack. If a primary power failure occurs, the redundant partner assumes the full electrical load instantly. This seamless failover prevents system reboots and maintains process continuity in high-stakes environments like chemical refining and power generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs provide real-time health monitoring. The module signals the DCS if output voltage drifts or if internal thermal thresholds exceed safe limits, allowing maintenance teams to intervene before a hardware failure impacts production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTechnicians can replace a faulty PW482-10 S2 module while the system remains under power. This capability eliminates the need for plant-wide shutdowns during routine power supply maintenance or hardware refreshes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the PW482-10 and the PW482-10 S2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The S2 revision indicates a hardware update that complies with newer international safety and reliability standards. While functionally similar, the S2 version offers improved internal component specifications and better thermal management for harsh industrial zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the PW482-10 S2 to replace a failed legacy power module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The PW482-10 S2 maintains backward compatibility with the CENTUM CS3000 and VP rack architectures. It serves as a direct drop-in replacement for older versions of the PW482 power supply series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require manual input voltage selection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit automatically handles standard AC ranges (100–120 VAC or 220–240 VAC). However, you must ensure the CENTUM rack is properly grounded according to Yokogawa’s installation manual to prevent electromagnetic interference (EMI) from affecting the 24VDC output.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43337659252826,"sku":"PW482-10 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/545..jpg?v=1778313051","url":"https:\/\/www.spareoil.com\/products\/5a-24vdc-power-supply-pw482-10-s2-yokogawa-centum","provider":"SpareOil Automation","version":"1.0","type":"link"}