{"product_id":"6-channel-paperless-recorder-yokogawa-fx1006-4-3-l-fx1000","title":"6-Channel Paperless Recorder | Yokogawa FX1006-4-3-L FX1000","description":"\u003ch2\u003eYokogawa FX1006-4-3-L FX1000 Paperless Recorder\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa FX1006-4-3-L\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFX1006\u003c\/strong\u003e Data Acquisition\/Recorder Module, operates as a dedicated hardware component for recording and displaying analog and digital signals from field instruments within process control topologies. The instrument executes direct physical acquisition across 6 universal input channels, digitizing raw voltage, current, and temperature sensor inputs via an internal 16-bit A\/D conversion matrix. By maintaining distinct galvanic boundaries between input circuits, the unit logs high-resolution trend measurements directly to localized internal non-volatile memory and removable CompactFlash media.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric designations assigned to the primary model define specific factory configurations and built-in interface sub-systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFX1006:\u003c\/strong\u003e 6-channel universal input configuration with a minimum 1 s measurement sweep interval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-4:\u003c\/strong\u003e Integrated CompactFlash (CF) external storage medium slot supplied with a 512 MB memory card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-3:\u003c\/strong\u003e Multi-language firmware package supporting localized units (including deg F and Daylight Saving Time options).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-L:\u003c\/strong\u003e High-withstand voltage input isolation option rated at 400 VAC (50\/60 Hz) for 1 min between measurement terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/A1:\u003c\/strong\u003e Hardware extension card providing 2 points of Form C contact alarm relay outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/M1:\u003c\/strong\u003e Internal mathematical processor license containing localized computational and automated report firmware operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/USB1:\u003c\/strong\u003e Front panel type A USB communication port interface link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFX1006-4-3-L (Configured with options \/A1\/M1\/USB1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e144 mm x 144 mm x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePaperless Recorders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 universal channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, DC Voltage, 4-20 mA DC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Panel\u003c\/td\u003e\n\u003ctd\u003e5.7-inch TFT color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet, USB, RS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC nominal (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Array\u003c\/td\u003e\n\u003ctd\u003eInternal Flash Memory + 512 MB CF Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Instrumentation Interface \u0026amp; Logic Attributes\u003c\/h3\u003e\n\u003cp\u003eThe multi-channel input stage implements programmable sensor terminations engineered to accept the 4-20 mA HART loop protocol when driven by external shunt resistors. Channel-to-channel isolation networks construct robust electrical partitions that inhibit high-voltage common-mode drift, stopping cross-channel telemetry errors during high-temperature measurement operations. For primary temperature tracking loops, integrated cold junction compensation (CJC) circuits dynamically correct thermoelectromotive drift directly at the copper screw terminals, processing raw thermocouple sensor inputs into linearized data streams for transmission over the network architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the recording engine prevent data corruption if the primary 100-240 VAC power source fails unexpectedly?\u003c\/p\u003e\n\u003cp\u003eA: The device automatically logs incoming data into non-volatile internal flash memory. This design structure prevents historical trends and operational parameters from being erased during blackouts, allowing the instrument to resume processing lines immediately upon power restoration.\u003c\/p\u003e\n\u003cp\u003eQ: What action must a field technician execute to process standard 4-20 mA inputs on the universal termination board?\u003c\/p\u003e\n\u003cp\u003eA: The universal input pins operate natively as high-impedance voltage terminals. To acquire standard 4-20 mA current loops, installers must bridge the positive and negative channel screws with an external 250 Ohm precision shunt resistor to scale the loop current into a proportional 1-5 VDC input signal.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical protection is provided by the specific -L suffix option when multi-channel inputs share a common wire way?\u003c\/p\u003e\n\u003cp\u003eA: The -L suffix designates a reinforced galvanic isolation barrier capable of sustaining up to 400 VAC (50\/60 Hz) between individual input terminal sets for 1 min. This hardware specification ensures that localized phase-to-ground short circuits on one sensor cable will not migrate into and destroy the processing electronics of the other five channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Ground Setup:\u003c\/strong\u003e Bolt the recorder body securely into the panel cutout, verifying that the rear grounding screw links directly to the primary structural earth bus bar through a heavy-gauge copper wire to route high-frequency line noise away from the A\/D converters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrain Wire Shield Matrix:\u003c\/strong\u003e Terminate all incoming thermocouple and RTD instrument cable shields directly onto an external uninsulated ground plate. Do not allow bare shield wire strands to project into the active terminal strip connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Signal Conductors:\u003c\/strong\u003e Guide all low-voltage sensor cabling inside dedicated plastic wiring pathways, maintaining a strict minimum clearance space of 200 mm from high-amperage AC power supply conductors or electrical drive loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Screw Torque:\u003c\/strong\u003e Adjust all terminal strip retention screws to the specified manufacturer tightness limits to prevent micro-disconnections or thermal measurement shifts under conditions of regular industrial vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43660835979354,"sku":"FX1006-4-3-L","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/548.1_70d13863-641e-4167-8ec6-ee5f92300b2c.jpg?v=1784084481","url":"https:\/\/www.spareoil.com\/products\/6-channel-paperless-recorder-yokogawa-fx1006-4-3-l-fx1000","provider":"SpareOil Automation","version":"1.0","type":"link"}