{"product_id":"6060024-hima-safety-cpu-module-new-original-stock","title":"6060024 HIMA Safety CPU Module | New \u0026 Original Stock","description":"\u003ch2\u003eHIMA 6060024 H51q Series Safety CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA 6060024\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e6060024\u003c\/strong\u003e Safety-Related CPU Module, serves as the primary \u003cstrong\u003e6060024\u003c\/strong\u003e Safety CPU Module utilized to execute core logic processing across HIMA H51q Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6060024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafety-Related CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit ARM9 running at 400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e1 MB total capacity (User, OS, Data partitions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet\/IP, PROFINET, Modbus TCP, RS-485, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output Interface\u003c\/td\u003e\n\u003ctd\u003eConfigurable multi-channel digital input\/output mapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 75 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe 6060024 microprocessor card complies with IEC 61508 SIL 3 and EN 954-1 Category 4 functional safety criteria. Operating under a continuous hardware monitoring configuration, the 32-bit ARM9 core executes logic routines alongside hardware-driven diagnostic engines. If an asymmetric internal data transaction or hardware memory parity error registers, the module initiates immediate fail-safe state execution, shutting down active data lines and driving connected digital outputs to a de-energized low state to ensure total control loop isolation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 6060024 module support online hot-swap capabilities inside the H51q rack assembly?\u003c\/p\u003e\n\u003cp\u003eA: No. Hot-swapping the primary safety-related CPU module while the control plane is energized can interrupt active safety-instrumented functions and trigger a global platform trip. Power down the subsystem prior to module handling.\u003c\/p\u003e\n\u003cp\u003eQ: How is the execution sequence structured when configuring redundancy with two 6060024 modules?\u003c\/p\u003e\n\u003cp\u003eA: Redundant configurations operate in a tightly synchronized active-spare mode. The primary unit mirrors its safety stack across the backplane bus, allowing the standby CPU to assume control with zero latency if a diagnostic fault occurs on the active processor.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication protocols are embedded directly within the hardware logic layer for DCS interfacing?\u003c\/p\u003e\n\u003cp\u003eA: The physical network interfaces provide native, concurrent hardware-level processing for PROFINET, Ethernet\/IP, and Modbus TCP communication protocols.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment and DIN Rail Fixing:\u003c\/strong\u003e Align the module rails carefully with the chassis slots or 35 mm top-hat DIN rail section. Depress the mechanical latch completely until a tactile locking engagement isolates the card from industrial vibration forces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Segment Isolation:\u003c\/strong\u003e Route Ethernet\/IP and PROFINET communication cabling inside separate physical wire paths isolated from high-voltage AC distribution power drops to limit electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Impedance Frame Earthing:\u003c\/strong\u003e Ground the panel mounting structure to a master low-impedance safety instrumented ground bar. Ensure paint is scraped from metal mating surfaces to verify electrical continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Boundaries and Convection Paths:\u003c\/strong\u003e Provide a minimum of 50 mm clearance gaps above and below the module ventilation openings to maintain structural convective cooling flows across the -40 to +70 deg C operational limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43426679357530,"sku":"6060024","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/278._0b0f5024-b88f-4602-8262-3feddf052e3d.jpg?v=1779947028","url":"https:\/\/www.spareoil.com\/products\/6060024-hima-safety-cpu-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}