{"product_id":"62100-hima-analogue-limit-monitor-new-original-stock","title":"62100 HIMA Analogue Limit Monitor | New \u0026 Original Stock","description":"\u003ch2\u003eHIMA 62100 PLANAR4 Safety System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA 62100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e62100\u003c\/strong\u003e Analogue Limit Monitor, operates as a dedicated hardware component for over, under, and range limit values monitoring within PLANAR4 Safety System networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e62100 (Alternate Part No: 984162100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e2-Fold Analogue Limit Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eVoltage: 0-5.5 V, 1-5.5 V; Current: 0-22 mA, 4-22 mA (250 Ohm shunt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Channels\u003c\/td\u003e\n\u003ctd\u003e2 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eReference error \u0026lt;= 0.25% (at +25 deg C); Operating error \u0026lt;= 0.4% (-25 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms (Limit module logic); \u0026lt; 100 ms typical (System processing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contacts\u003c\/td\u003e\n\u003ctd\u003e2 relay outputs (100 mA each, fail-safe contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eDual-processor 1oo2 redundant design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal, 170 mA (~4.1 Watts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C (Extended range: -25 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm x 100 mm x 22.5 mm (3U high, 4SU wide subrack form)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe 62100 internal circuitry utilizes a dual-processor 1oo2 redundant design certified to meet IEC 61508 SIL 3 operational parameters. The analogue front-end executes continuous line diagnosis routines across the 4-22 mA or 1-5.5 V sensing paths to identify open-circuit wire breaks or short-circuit signal anomalies. If any discrepancy manifests between the independent internal processing nodes or if a loop fault triggers, the module forces its active relay contacts to open, initiating a fail-safe state execution to drop safety loops into a de-energized shutdown sequence instantly. Complete galvanic isolation separates the incoming analogue channels from the output loops to eliminate fault propagation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the line diagnosis function enabled or disabled on the 62100 analogue loop inputs?\u003c\/p\u003e\n\u003cp\u003eA: Line diagnosis parameters depend on the configured physical signal range. Selecting a live-zero scale (4-22 mA or 1-5.5 V) engages the hardware comparison window, whereas true-zero paths (0-22 mA or 0-5.5 V) bypass the line diagnosis mechanism.\u003c\/p\u003e\n\u003cp\u003eQ: Is online hot-swapping permitted for the 62100 card during continuous turbine or compressor protection monitoring?\u003c\/p\u003e\n\u003cp\u003eA: Yes, if the 62100 is mounted within an engineered redundant architecture configuration. Extraction of a single card while the chassis rail is energized will break that specific 1oo2 logic link but will not disrupt remaining rack backplane power lines, provided appropriate process overrides are implemented.\u003c\/p\u003e\n\u003cp\u003eQ: What physical reaction occurs within the output relays when the 24 VDC nominal module power drops below the low-voltage limit?\u003c\/p\u003e\n\u003cp\u003eA: A power drop below the operational 18 VDC threshold de-energizes the internal coils, causing both independent relay outputs to immediately drop open into their hardwired fail-safe state execution configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Alignment and Mechanical Capture:\u003c\/strong\u003e Slide the module block cleanly along the 19-inch subrack metal guide rails or snap directly onto standard 35 mm DIN rail. Lock the retention tabs to damp high-frequency physical displacement caused by heavy industrial plant machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue Loop Shield Termination:\u003c\/strong\u003e Run all 4-20 mA and low-voltage field signal cables inside dedicated twisted-pair shielded bundles. Land the copper shield braid cleanly at the central marshalling plate instrument ground bus only to negate ground loop currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShunt Resistor Path Protection:\u003c\/strong\u003e When configuring current inputs, verify the integrity of the integrated 250 Ohm internal shunt network connection. Prevent external voltage transients from over-driving the input terminals to maintain accuracy tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Convection Spacing:\u003c\/strong\u003e Ensure adjacent high-heat components are positioned with a minimum 20 mm lateral clearance gap to protect the 62100 multi-processor components from structural degradation when operating near the +70 deg C limit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43426721529946,"sku":"62100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/279._cbbacf3c-3449-4f3b-a82d-27984f8d53be.jpg?v=1779948740","url":"https:\/\/www.spareoil.com\/products\/62100-hima-analogue-limit-monitor-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}