{"product_id":"6es7153-2ba02-0xb0-siemens-et-200m-interface-module-new-stock","title":"6ES7153-2BA02-0XB0 Siemens ET 200M Interface Module | New Stock","description":"\u003ch2\u003eSIEMENS 6ES7153-2BA02-0XB0 SIMATIC PLC INTERFACE MODULE\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSIEMENS 6ES7153-2BA02-0XB0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIM 153-2 DP HF\u003c\/strong\u003e ET 200M Interface Module, operates as a dedicated hardware component for discrete data routing and subsystem electrical distribution within SIMATIC distributed I\/O networks. The module establishes the primary physical and logical bridge between the central controller and up to 12 S7-300 expansion modules via the PROFIBUS DP fieldbus architecture. By executing high-speed, deterministic cyclical exchange of I\/O image tables, the assembly Offloads localized network transactions from central CPU execution loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7153-2BA02-0XB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e40 x 125 x 117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.5 W typical power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (nominal range 20.4 to 28.8 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 600 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Current\u003c\/td\u003e\n\u003ctd\u003eMax. 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 12 S7-300 modules max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Space Volume\u003c\/td\u003e\n\u003ctd\u003e244 bytes input \/ 244 bytes output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Layer Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP (RS-485 format)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Velocity Rates\u003c\/td\u003e\n\u003ctd\u003eUp to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVendor Identification (VendorID)\u003c\/td\u003e\n\u003ctd\u003e801Eh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Network Velocity Profiles\u003c\/h3\u003e\n\u003cp\u003eThe device incorporates specific internal backplane bus communication velocity licenses that handle dense payload profiles across distributed ET 200M assemblies. It coordinates up to 128 time-stamped digital inputs per station with a resolution accuracy threshold down to 1 ms across ≤8 modules, shifting to 10 ms when handling the full 12-module expansion limit. The underlying hardware firmware flash compatibility allows concurrent routing of expanded quantity structures for HART auxiliary variables and direct slave-to-slave data exchange via deterministic PROFIBUS networks, supporting the integration of 64-channel high-density modules at a fixed density mapping of 32 signals per physical rack slot.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 6ES7153-2BA02-0XB0 handle active failover transitions inside a redundant PROFIBUS DP topology?\u003c\/p\u003e\n\u003cp\u003eA: The module contains dedicated hardware switching logic that monitors the status of twin-line connections when paired with an identical interface node on a redundant bus module assembly. If the primary master drops carrier frequency, the standby module executes a zero-bounce, bump-free switchover that maintains the active backplane state without altering current I\/O positions.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current constraints when deploying the maximum limit of twelve S7-300 modules?\u003c\/p\u003e\n\u003cp\u003eA: The module internal logic regulates incoming 24 VDC down to a 5 VDC plane to supply the internal backplane logic with a maximum current ceiling of 1.5 A. If the cumulative power draw of the connected logic cards exceeds 1.5 A, external isolation components or auxiliary supply clamps must be introduced to prevent thermal overload shutdowns.\u003c\/p\u003e\n\u003cp\u003eQ: Is this older High Feature hardware revision compatible with modern STEP 7 configuration suites?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is fully defined within standard Siemens engineering software utilities using GSD reference file SI04801.GSG. It can be integrated into replacement branches without requiring manual firmware modifications, provided the target master configuration respects the standard address constraints.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnaps securely onto standard S7-300 or active bus module rails; verify the rear ground slide makes solid contact with the metal rack assembly.\u003c\/li\u003e\n\u003cli\u003eSet the binary station node address clearly via the front-facing DIP switch bank (range 1 to 125) before energizing the 24 VDC input lines.\u003c\/li\u003e\n\u003cli\u003eFasten incoming PROFIBUS network lines using sub-D connectors fitted with internal, low-impedance termination resistors at the end nodes.\u003c\/li\u003e\n\u003cli\u003eRoute the internal 24 VDC power feed lines through separate panel tracking channels to avoid cross-talk induction with adjacent signaling paths.\u003c\/li\u003e\n\u003cli\u003eMaintain free air clearance margins above and below the module enclosure to preserve the standard convective heat gradient at higher installation altitudes up to 3,000 m.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43438441726042,"sku":"6ES7153-2BA02-0XB0","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/183_cefd0638-ee12-46d4-b8b7-4b63729df3a2.jpg?v=1780275541","url":"https:\/\/www.spareoil.com\/products\/6es7153-2ba02-0xb0-siemens-et-200m-interface-module-new-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}