{"product_id":"6es7195-7hd10-0xa0-siemens-redundant-bus-module-new-original-stock","title":"6ES7195-7HD10-0XA0 Siemens Redundant Bus Module | New \u0026 Original Stock","description":"\u003ch2\u003eSiemens 6ES7195-7HD10-0XA0 SIMATIC DP Bus Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for holding two redundant IM153-2 interface modules in SIMATIC DP ET 200M distributed I\/O systems, the \u003cstrong\u003eSiemens 6ES7195-7HD10-0XA0\u003c\/strong\u003e (\u003cstrong\u003eSiemens 6ES7195-7HD10-0XA0\u003c\/strong\u003e Bus Module) provides direct physical and electrical execution of hot-swapping maneuvers during RUN operating time.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7195-7HD10-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.133 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e97 mm x 92 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial limits per ET 200M specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive backplane routing component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eTwo IM153-2 interface modules (redundant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP backplane bus routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctionality\u003c\/td\u003e\n\u003ctd\u003eRemoval and insertion during RUN operating time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eEMV, China RoHS, FM (Hazardous Locations), NK, CCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Backplane Continuity\u003c\/h3\u003e\n\u003cp\u003eThe 6ES7195-7HD10-0XA0 acts as the dedicated active backplane backbone that establishes continuous electronic paths for localized sub-networks. When linked upstream to Profinet or PROFIBUS DP deterministic networks via the IM153-2 interface cards, this module sustains synchronous backplane bus communication velocity across all downstream I\/O modules. It prevents signal attenuation or timing jitter during runtime operations. By implementing isolated electrical traces between the dual interface module slots, the hardware allows one IM153-2 to fail or be extracted while the secondary redundant card maintains uninterrupted deterministic network data exchanges with the master controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does extracting one of the two installed IM153-2 modules during RUN mode break the backplane communication to the downstream I\/O slices?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal circuitry of the module isolates each interface slot, allowing the active redundant IM153-2 to maintain continuous communication with the downstream I\/O backplane bus without interrupting process data flow.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current load limitations imposed by this module?\u003c\/p\u003e\n\u003cp\u003eA: This component functions as a passive physical routing and connection matrix; it does not consume active current from the system backplane, but it is limited by the maximum bus current passing throughput specified by the SIMATIC ET 200M platform.\u003c\/p\u003e\n\u003cp\u003eQ: Can standard 40 mm wide digital or analog I\/O modules be installed directly onto this specific bus module?\u003c\/p\u003e\n\u003cp\u003eA: No. The mechanical footprint and internal connector pinout of the 6ES7195-7HD10-0XA0 are engineered exclusively to accept up to two IM153-2 interface modules for redundant setups.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Bus Rail Mounting:\u003c\/strong\u003e Mount the unit exclusively on the designated active bus module rail. Lower the top rear hook onto the rail guide and slide the unit laterally into engagement with the adjacent module connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Secure a solid functional ground connection via the DIN rail mounting mechanism to ensure proper shielding execution against electrical noise across the PROFIBUS DP backplane bus links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion Alignment:\u003c\/strong\u003e Align the rear pins of the IM153-2 interface module perpendicular to the bus module face before seating the hardware. Do not insert modules at an angle, as this can cause permanent mechanical deformation of the backplane bus connection pins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43438454440026,"sku":"6ES7195-7HD10-0XA0","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/187._ac56ae72-7f8d-4f72-91f2-78d62e24fc7a.jpg?v=1780276826","url":"https:\/\/www.spareoil.com\/products\/6es7195-7hd10-0xa0-siemens-redundant-bus-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}