{"product_id":"8-channel-2at-fused-power-dist-fc-pdb-0824-honeywell","title":"8-Channel 2AT Fused Power Dist | FC-PDB-0824 Honeywell","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-PDB-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an authoritative 8-channel power distribution board engineered for the Honeywell Experion PKS and C300 controller ecosystems. It serves as a mechanical necessity for managing DC power across high-density I\/O racks, providing a centralized point for distributing regulated 24 VDC to critical field devices and modules. Equipped with individual fuse protection for each channel, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-PDB-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that localized electrical faults do not compromise the entire control segment. Its DIN-rail mountable design and industrial-grade Weidmuller connectors make it a trustworthy component for mission-critical power management in refineries, chemical processing plants, and utility power generation facilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFC-PDB-0824\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8-Channel Power Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS, C300 Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–30 VDC (24 VDC Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Distribution Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFuse Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 2 AT (Slow acting, 5 x 20 mm) per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Connector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pole header (Weidmuller BVZ 7.62\/02F SW)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eField Connector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pole socket block (Weidmuller BL 5.08\/2 SN OR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN EN Rails TS32 \/ TS35 × 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e94 x 109 x 71 mm (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUsed Rail Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 mm (3.74 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE; UL, TUV, CSA (Pending)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering and Power Distribution Strategy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e: Each of the 8 output channels on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-PDB-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis protected by a slow-acting 2A fuse. This expertise-driven design ensures that if a field-side actuator or sensor shorts out, only that specific branch is disconnected, preserving the operational integrity of the remaining 7 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Reliability\u003c\/strong\u003e: The board utilizes high-quality Weidmuller connectors with integrated keying (KO BV\/SV7.62). This is a mechanical necessity to prevent accidental cross-wiring or incorrect module insertion during high-pressure maintenance windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: The board facilitates clean power distribution by providing a centralized isolation point. This helps mitigate the propagation of electrical noise and ground loops, which is authoritative for maintaining stable signal acquisition in sensitive C300 I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Mounting\u003c\/strong\u003e: Designed for universal cabinet integration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-PDB-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efits both TS32 and TS35 DIN rails. With a required rail length of 95 mm, it allows engineers to optimize space within remote instrument enclosures (RIE) or local control panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of fuses should be used with the FC-PDB-0824?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board is designed for 5 x 20 mm fuses. To comply with technical specifications and ensure proper protection of the 24 VDC rails, use slow-acting fuses with a maximum rating of 2 AT.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this board be used in redundant power configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In high-availability systems, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-PDB-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits are often deployed to distribute power from redundant DC sources, ensuring that a single power supply failure does not result in a loss of field device power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the input connectors keyed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The input headers feature keying to ensure the power source is connected with correct polarity, which is a trustworthy safeguard against reverse-voltage damage to downstream components.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43070789615706,"sku":"FC-PDB-0824","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/336._c14e4516-b47c-4b1e-9646-5ca5524f6923.jpg?v=1773976476","url":"https:\/\/www.spareoil.com\/products\/8-channel-2at-fused-power-dist-fc-pdb-0824-honeywell","provider":"SpareOil Automation","version":"1.0","type":"link"}