{"product_id":"8-channel-power-distribution-board-honeywell-fc-pdb-0824","title":"8-Channel Power Distribution Board | Honeywell FC-PDB-0824","description":"\u003ch2\u003eHoneywell FC-PDB-0824 Experion PKS Power Distribution Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi-channel DC voltage branch isolation in Experion PKS and C300 architectures, the \u003cstrong\u003eHoneywell FC-PDB-0824\u003c\/strong\u003e (\u003cstrong\u003eFC-PDB-0824\u003c\/strong\u003e 8-Channel Power Distribution Board) provides direct physical\/electrical execution. The assembly splits a main 24 VDC supply rail into eight independently fused branch outputs to power field transmitters, switches, and remote I\/O devices. Each channel incorporates individual fuse protection to isolate short-circuit conditions to a single loop, maintaining continuous power distribution across adjacent operating channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-PDB-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e94 mm x 109 mm x 71 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution board (Losses determined by fuse resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 independently fused outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eMax 2 AT (Slow-acting, 5 x 20 mm) per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003e2-pole header (Weidmuller BVZ 7.62\/02F SW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connector\u003c\/td\u003e\n\u003ctd\u003e2-pole socket block (Weidmuller BL 5.08\/2 SN OR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDIN EN Rails TS32 \/ TS35 x 7.5 (95 mm rail length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE (UL, TUV, CSA Pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and HART Loop Bus Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe board layout provides clean DC voltage routing to field loops, preventing ground loop formation and common-mode voltage propagation across adjacent channels. By maintaining stable DC bus lines and low signal attenuation, the board supports overlay digital communications on field wiring, ensuring full compatibility with 4-20 mA HART loop protocol instruments and associated Experion PKS DCS carrier interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific fuse type and physical size does the FC-PDB-0824 accept?\u003c\/p\u003e\n\u003cp\u003eA: The board accepts 5 x 20 mm slow-acting fuses rated up to a maximum of 2 AT per individual output channel.\u003c\/p\u003e\n\u003cp\u003eQ: Can the input connector accept reversed polarity power connections?\u003c\/p\u003e\n\u003cp\u003eA: The input Weidmuller BVZ header features mechanical keying (KO BV\/SV7.62) to physically prevent misaligned insertion or reverse-polarity wiring.\u003c\/p\u003e\n\u003cp\u003eQ: Does replacing a blown channel fuse require powering down the entire input supply bus?\u003c\/p\u003e\n\u003cp\u003eA: No. Because each output circuit operates through an independent fuse holder, technicians can pull and replace a blown fuse for a specific channel without interrupting the main 24 VDC bus powering the remaining seven channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSnap the board onto standard TS32 or TS35 x 7.5 DIN rail sections, allowing a minimum rail length of 95 mm. Secure all input power conductors to the 2-pole Weidmuller header, verifying that the mechanical keying tabs align correctly before applying torque. Connect field loop cabling to the 2-pole output socket blocks, keeping power supply cables routed separately from sensitive analog signal cables to eliminate inductive noise coupling. Ensure cabinet airflow maintains local ambient temperatures between 0 deg C and +60 deg C.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43070789615706,"sku":"FC-PDB-0824","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/336_b763e6ac-d8e1-4333-a948-fe57bd79bffa.jpg?v=1773976476","url":"https:\/\/www.spareoil.com\/products\/8-channel-power-distribution-board-honeywell-fc-pdb-0824","provider":"SpareOil Automation","version":"1.0","type":"link"}