{"product_id":"80097-01-bently-nevada-six-channel-thermocouple-rtd-monitor","title":"80097-01 Bently Nevada Six-Channel Thermocouple\/RTD Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 80097-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSix-Channel Temperature Monitoring Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emachinery protection racks. This module provides continuous, real-time thermal oversight of critical rotating assets by processing signals from Resistance Temperature Detectors (RTDs) and thermocouples. It identifies abnormal temperature rises in bearings, casings, and motor windings before mechanical failure occurs. By integrating directly into the 3300 system backplane, the 80097-01 delivers localized alarm logic and scalable analog outputs, forming a vital component of proactive condition monitoring and predictive maintenance strategies.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 80097-01 utilizes advanced signal conditioning to maintain data accuracy across a wide measurement spectrum.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80097-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTDs (100 \u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e Platinum) and Thermocouples (Type J, K, T, etc.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–200 °C to +850 °C (Sensor dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndependent Alert and Danger levels per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScaled Analog Voltage \/ Configurable Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+24 VDC (Backplane supplied)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 Series Rack-mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimultaneous Multi-Point Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module tracks six independent temperature zones through a single rack slot. This high-density architecture allows engineers to monitor multiple bearing points or motor phases simultaneously, reducing the total hardware footprint required for comprehensive machinery protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Sensor Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 80097-01 accepts both RTD and thermocouple inputs. This flexibility eliminates the need for separate hardware modules when a machine utilizes different sensor types for casing and bearing measurements, simplifying spare parts inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Alarm Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel features dedicated Alert and Danger setpoints. When temperatures breach these thresholds, the module triggers integrated relays or system alarms instantly. This localized hardware-level logic ensures that protection actions occur independently of external software, maximizing system reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada builds the 80097-01 to thrive in harsh industrial environments. The circuitry rejects electromagnetic interference (EMI) and maintains precision even in the presence of the high-vibration and humidity levels typical of steam turbine halls and compressor stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the Bently Nevada 80097-01 supplied as 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware in factory-sealed packaging. Every module includes a 12-month factory warranty to guarantee the safety of your critical rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix RTDs and Thermocouples on the same 80097-01 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the module hardware supports both types, the configuration typically requires specific input terminal blocks or jumpers to match the sensor characteristics. Always refer to your specific 3300 rack wiring diagram to ensure proper impedance matching for the selected sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does this module assist in predictive maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 80097-01 provides scaled analog outputs that interface with Data Acquisition Systems (DAQ). By tracking historical temperature trends, maintenance teams can identify gradual thermal degradation in bearings, allowing for scheduled interventions rather than emergency shutdowns.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require manual calibration during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Bently Nevada modules come factory-calibrated. However, upon installation into a 3300 rack, you must configure the zero and span settings to match your specific sensor range and required alarm setpoints using the system's calibration procedures.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43250905088090,"sku":"80097-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/285._b713233a-7227-4603-b80b-ed9dad0383bb.jpg?v=1776837584","url":"https:\/\/www.spareoil.com\/products\/80097-01-bently-nevada-six-channel-thermocouple-rtd-monitor","provider":"SpareOil Automation","version":"1.0","type":"link"}