{"product_id":"8202-ho-is-pac8000-analog-output-brand-new-original","title":"8202-HO-IS PAC8000 Analog Output Brand New Original","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson 8202-HO-IS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance analog output interface within the PAC8000 modular I\/O family. This module provides eight intrinsically safe 4–20 mA channels specifically designed to drive field devices such as I\/P converters, actuators, and valves located in Zone 1\/Division 1 hazardous areas. By integrating HART® pass-through capability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8202-HO-IS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables advanced digital diagnostics and device status reporting directly through the analog loop. We offer this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment, ensuring full compliance with ATEX, IECEx, and North American safety standards for critical process control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (PAC8000 \/ MTL \/ GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8202-HO-IS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Single-ended Analog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA nominal (Full range: 1–22 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (@ 25 °C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±20 μA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–650 Ω Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDrive Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥13 V at 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHART® Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHART Pass-through (variables \u0026amp; status)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 V AC (Channel to Railbus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntrinsically Safe (ATEX\/IECEx\/UL\/CSA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Hazardous Area Control\u003c\/strong\u003e: The intrinsically safe circuitry eliminates the need for external barriers when connecting to field devices in explosive atmospheres. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8202-HO-IS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elimits energy levels to prevent ignition, simplifying cabinet design and reducing hardware footprints in offshore and refinery applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART® Enabled Diagnostics\u003c\/strong\u003e: The module maintains transparent HART® communication. This allows maintenance teams to perform remote configuration and retrieve \"Smart\" diagnostics from actuators and I\/P converters without interrupting the 4-20mA control signal or entering hazardous zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Fault Detection\u003c\/strong\u003e: Built-in diagnostics continuously monitor the field wiring integrity. The module immediately detects and reports open-circuit conditions (threshold \u0026gt;685 Ω) and loads that drift beyond the driveable range, facilitating rapid troubleshooting before process deviations occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Resilience\u003c\/strong\u003e: Engineered for reliability, the module operates across a wide temperature range of -40 °C to +70 °C. It features a temperature stability rating of ±0.006% per °C, ensuring precision control in both arctic and tropical industrial climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if my field device loop exceeds 650 Ω?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module detects the high resistance as an open circuit or a \"beyond range\" fault. To ensure precise 4-20mA control, verify that the total loop impedance, including field wiring and device resistance, remains below the 650 Ω threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes HART communication slow down the module's response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In standard analog mode, the module provides an 80 ms response time. When operating in HART mode for digital data pass-through, the response time extends to 1 second to accommodate the digital signal overlay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with existing PAC8000 carriers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8202-HO-IS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures the standard PAC8000 form factor and plugs directly into the PAC8000 carrier system. It integrates seamlessly with the existing Railbus for power and data communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43131273936986,"sku":"8202-HO-IS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/331._3c1d8fd6-326d-4b3d-b2c1-43e055225bcf.jpg?v=1774508459","url":"https:\/\/www.spareoil.com\/products\/8202-ho-is-pac8000-analog-output-brand-new-original","provider":"SpareOil Automation","version":"1.0","type":"link"}