{"product_id":"8237-1369-woodward-protech-gii-datasheet-technical-manual","title":"8237-1369 Woodward ProTech-GII Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eWoodward 8237-1369 ProTech-GII Overspeed Protection System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8237-1369\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8237-1369\u003c\/strong\u003e Overspeed Protection System, operates as a dedicated hardware component for fail-safe speed monitoring within gas, steam, and hydro turbine platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8237-1369\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.5 kg (14.3 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard ProTech-GII rackmount chassis footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConfigured via dual redundant 24 VDC inputs (18-32 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoting Logic\u003c\/td\u003e\n\u003ctd\u003e2-out-of-3 (2oo3) Triple Modular Redundant (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Sensing Inputs\u003c\/td\u003e\n\u003ctd\u003e3 x Independent passive or active MPU inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003eTrip relays (Form A\/C), alarm relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003eConfigurable 4-20 mA speed readouts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU (RS-485) and Modbus TCP (Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN61000-6-2 (Immunity), EN61000-6-4 (Emissions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Drives, Governors, and Speed Control Properties\u003c\/h3\u003e\n\u003cp\u003eThe device processes high-resolution frequency profiles from three independent magnetic pickups to regulate trip relay states on critical rotating assets. The 2-out-of-3 (2oo3) voting logic structures the internal actuator loop feedback response time limits, achieving a sub-12 ms instantaneous trip response upon registering an overspeed threshold breach. To insulate the processing core from high-frequency electromagnetic interference generated by industrial drive infrastructure, the unit integrates internal harmonic distortion suppression modules alongside EN61000-6-2 certified shielding layers. Thermal heat sink dissipation profiles across the IP56-rated housing maintain steady-state logic tracking without introducing processing lag under continuous maximum temperature environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal 2oo3 voting logic isolate a single sensor failure without tripping the prime mover?\u003c\/p\u003e\n\u003cp\u003eA: The Triple Modular Redundant (TMR) architecture continuously runs independent speed tracking algorithms on all three MPU inputs. If one sensor goes offline or transmits erroneous values, the internal 2oo3 logic overrides the single fault, allowing the remaining two channels to maintain protection monitoring and eliminate nuisance trips.\u003c\/p\u003e\n\u003cp\u003eQ: Can the automated periodic self-tests be executed while the turbine is online?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware executes internal self-testing routines that verify the electrical and functional integrity of the trip relays and internal logic boards. These procedures are conducted safely while the asset remains in service, without risking an accidental shutdown.\u003c\/p\u003e\n\u003cp\u003eQ: What are the parameters for dual power input redundancy on this system?\u003c\/p\u003e\n\u003cp\u003eA: The device contains separate, isolated power terminals designed to accept dual redundant 24 VDC nominal lines. The hardware functions continuously across an 18 VDC to 32 VDC range, executing automatic, bumpless switchover if one power source experiences a localized dropout.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPU Terminal Shielding Constraints:\u003c\/strong\u003e Route the three independent magnetic pickup lines using dedicated twisted-pair, shielded cables. Terminate each cable shield exclusively at the designated ground bar on the ProTech-GII chassis to minimize electrical cross-talk and maintain clean input signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP56 Enclosure Sealed Routing:\u003c\/strong\u003e To maintain the IP56 ingress protection rating against dust and high-pressure water jets, use liquid-tight conduit hubs or compression glands for all cable entries into the terminal cabinet. Seal any unused entry ports to prevent moisture accumulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Communication Separations:\u003c\/strong\u003e Install Modbus TCP Ethernet and Modbus RTU RS-485 cables in separate low-voltage wire trays away from the primary trip relay outputs and heavy AC power lines to safeguard data transmission interfaces from inductive noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42870826369114,"sku":"8237-1369","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/196_f777aa44-05a8-436e-b8a6-8aaf5089b38b.jpg?v=1772766945","url":"https:\/\/www.spareoil.com\/products\/8237-1369-woodward-protech-gii-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}