{"product_id":"8400-016-woodward-speed-control-module-new-original-stock","title":"8400-016 Woodward Speed Control Module | New \u0026 Original Stock","description":"\u003ch2\u003eWoodward 8400-016 Digital Speed Control \u0026amp; Synchronizer Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8400-016\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8400-016\u003c\/strong\u003e Digital Speed Control \u0026amp; Synchronizer, operates as a dedicated hardware component for industrial engine governing and automated grid synchronization within Woodward power management networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8400-016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e210 x 160 x 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified (industrial engine-room envelope)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal (18-32 VDC Operating Range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Output\u003c\/td\u003e\n\u003ctd\u003eLow-current PWM for proportional actuators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady-State Accuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.25% of rated speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization Logic\u003c\/td\u003e\n\u003ctd\u003eAutomatic matching of Frequency, Phase, and Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRedundant Ethernet, Dual Serial (RS-232 \u0026amp; RS-422)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\/TCP, Woodward Proprietary Protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated MAP Limiting, Torque Limiting, and Start Fuel Limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eIP56 Sealed Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eRated for Class 1, Division 2 environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Drives \u0026amp; Governors Properties\u003c\/h3\u003e\n\u003cp\u003eThe Woodward 8400-016 incorporates specialized internal thermal heat sink dissipation profiles to maintain computation stability within its IP56 sealed enclosure. Engineered to manage diesel, gas, and turbine engine assets, the hardware regulates speed variations by delivering a low-current Pulse Width Modulation (PWM) signal to proportional fuel actuators. This control loop executes rapid actuator loop feedback response metrics to correct for frequency variations, using integrated MAP limiting, torque limiting, and start fuel limiting subroutines to stabilize mechanical thermal profiles during volatile load transitions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle communication redundancy across distributed control networks? A: The module is equipped with dual redundant Ethernet interfaces alongside dual RS-232\/RS-422 serial ports. This configuration allows simultaneous data streaming via Modbus RTU and Modbus TCP\/IP protocols to distinct supervisory DCS and SCADA platforms, ensuring uninterrupted telemetry if a single network branch faults.\u003c\/p\u003e\n\u003cp\u003eQ: What specific engine safety and boundary limitations are handled by the processor? A: The unit processes active boundary control algorithms including Manifold Absolute Pressure (MAP) limiting, engine torque limiting, and start fuel fuel-enrichment limits. These safety boundaries restrict the actuator PWM output envelope to prevent over-fueling, mechanical overload, and thermal excursions during start cycles.\u003c\/p\u003e\n\u003cp\u003eQ: Can this synchronization module operate in environments exposed to moisture and dust ingress? A: Yes, the electronics are housed in an IP56 rated sealed enclosure designed to prevent dust accumulation and directional water spray from compromising internal processing circuits, making the unit suitable for marine and offshore bulkheads.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Orientation:\u003c\/strong\u003e Secure the IP56 enclosure onto a rigid, low-vibration bulkhead or panel interior using four heavy-duty mounting fasteners. Ensure the sealing gaskets are fully seated against the mounting interface to protect internal circuits from ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator PWM Cable Shielding:\u003c\/strong\u003e Connect the low-current PWM actuator output lines using dedicated twisted-pair, shielded copper conductors. Ground the outer shield at the governor chassis grounding bus terminal only to suppress high-frequency inductive noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Power Interface Fusing:\u003c\/strong\u003e Install an explicit overcurrent protection device on the incoming 24 VDC line before connecting to the module terminals. Ensure the feed line remains within the stable 18-32 VDC operating range under all cranking battery conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Link Isolation:\u003c\/strong\u003e Maintain physical routing separation between the Ethernet\/Serial data lines and any adjacent AC power cables or high-voltage switchgear generator leads to eliminate electromagnetic cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42870827581530,"sku":"8400-016","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/182_0b099892-760e-4cf6-b375-f02f2b3ac248.jpg?v=1772761164","url":"https:\/\/www.spareoil.com\/products\/8400-016-woodward-speed-control-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}