{"product_id":"873cc-biyfgz-foxboro-873cc-series-datasheet-technical-manual","title":"873CC-BIYFGZ Foxboro 873CC Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eFoxboro 873CC-BIYFGZ Conductivity Analyzer\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro 873CC-BIYFGZ\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e873CC\u003c\/strong\u003e Industrial Conductivity Analyzer, operates as a dedicated hardware component for continuous monitoring of liquid conductivity and resistivity within industrial process networks. The instrument processes electrochemical data streams by executing dual-channel sensor signal acquisition directly from contacting conductivity probes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e873CC-BIYFGZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.85 lbs (839 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 873 series panel mount dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via 100-240 V AC, 50\/60 Hz line feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eContacting conductivity and resistivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.00 uS\/cm to 20.00 mS\/cm (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Inputs\u003c\/td\u003e\n\u003ctd\u003eDual-channel (supports 独立 2 sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic via integrated RTD (100 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit high-contrast LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA analog; 2 configurable alarm relays (5 A at 125 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Communication\u003c\/td\u003e\n\u003ctd\u003eOptional RS-485 \/ Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 4XKI (corrosion-resistant metal variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThe analyzer incorporates a dual-sensor input structure designed to handle simultaneous, independent measurement routines across separate water lines without channel cross-talk. The analog output circuits are configured to translate electrochemical variables into isolated 4-20 mA loops for direct integration into DCS controllers. Automatic temperature compensation is maintained through continuous tracking of an integrated 100 Ohm RTD element, stabilizing the 16-bit algorithmic calculation of conductivity, resistivity, or removal rate when exposed to fluctuating process fluid temperatures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical parameters and ratings for the onboard alarm relays?\u003c\/p\u003e\n\u003cp\u003eA: The instrument features two independent, configurable alarm relays (normally open\/normally closed) rated to interrupt resistive loads up to 5 A at 125 V AC or 5 A at 30 V DC.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit preserve its configuration data during a complete primary power interruption?\u003c\/p\u003e\n\u003cp\u003eA: The analyzer utilizes non-volatile EEPROM memory to store all user-defined calibration factors, scale limits, and temperature compensation coefficients, preventing data loss without requiring internal backup batteries.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Grounding:\u003c\/strong\u003e Connect the dedicated internal ground terminal of the NEMA 4XKI metal housing directly to the plant instrument earth bus to suppress electromagnetic field interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Wire Shielding:\u003c\/strong\u003e Route sensor interconnecting cables through dedicated, grounded metal conduit. Keep sensor lines physically isolated from high-voltage AC power distribution conduits to eliminate signal degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout Alignment:\u003c\/strong\u003e Ensure the panel cutout matches factory dimensions exactly. Seat the integrated gasket flat against the panel surface before tightening the mounting brackets to maintain environmental sealing integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43454313332826,"sku":"873CC-BIYFGZ","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/400._fd3abf6d-2b54-4fe7-a985-566e90c26cb5.jpg?v=1780624673","url":"https:\/\/www.spareoil.com\/products\/873cc-biyfgz-foxboro-873cc-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}