{"product_id":"8u-tdoda1-honeywell-16ch-digital-output-connection-module","title":"8U-TDODA1 Honeywell 16CH Digital Output Connection Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8U-TDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core component of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS C300 I\/O subsystem\u003c\/strong\u003e. This 16-channel digital output module executes precise process control by delivering 24 VDC signals to field devices. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, sealed in factory packing to ensure maximum field longevity. It functions as the critical interface between the C300 controller logic and physical actuators, such as solenoids and relays, in high-stakes industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8U-TDODA1 \/ 8C-TDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWA Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307149-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Digital Output Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 0.5 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and channel-to-ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFieldbus Interface Module (FIM) to C300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, ATEX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNew \u0026amp; Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Downtime Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hot-swappable design allows technicians to replace modules without disrupting the power supply or interrupting the process loop. This feature eliminates scheduled outages during hardware refreshes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMission-Critical Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware architecture supports redundant I\/O configurations. If a primary module fails, the secondary unit takes control instantaneously, preventing system trips in volatile chemical or refining processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module integrates directly with the 8C-TDODA1 Termination Assembly. This modular approach separates field wiring from the active electronics, protecting the sensitive I\/O circuitry from wiring errors during initial installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LEDs provide real-time status updates for each channel. Engineers can quickly diagnose open circuits or shorted loads directly at the module faceplate, significantly reducing mean-time-to-repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 8U-TDODA1 require a specific chassis for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. You must install the module into a standard Honeywell C300 I\/O chassis. Ensure the chassis utilizes proper grounding to maintain signal integrity and satisfy ATEX\/UL safety requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module drive high-current contactors directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports up to 0.5 A per channel. While it handles most standard solenoids and small relays, you should use interposing relays for high-power contactors to prevent thermal overload on the module circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 8U-TDODA1 compatible with existing 8C-TDODA1 termination assemblies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 8U-TDODA1 module pairs with the 8C-TDODA1 (PWA 51307149-175) termination assembly to facilitate secure field wiring and signal distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle extreme environmental conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Honeywell builds this module for industrial rigor, supporting an operating temperature range of –20 °C to +70 °C. The internal isolation protects the C300 controller from field-side electrical surges and noise common in manufacturing plants.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43337622487130,"sku":"8U-TDODA1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/478._74b05756-f8b0-4ff1-b0a5-852ff1cc6862.jpg?v=1778310375","url":"https:\/\/www.spareoil.com\/products\/8u-tdoda1-honeywell-16ch-digital-output-connection-module","provider":"SpareOil Automation","version":"1.0","type":"link"}