{"product_id":"990-05-50-01-00-bently-nevada-990-2-wire-vibration-transmitter","title":"990-05-50-01-00 Bently Nevada 990 2-Wire Vibration Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-05-50-01-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e990\u003c\/strong\u003e 2-Wire Vibration Transmitter, operates as a dedicated hardware component for proximity probe signal conditioning and 4-20 mA current loop conversion within machinery protection networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e2-Wire Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp) vibration amplitude range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet) total calibrated system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eNo hazardous area approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-50-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eProportional 4-20 mA loop current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Interface\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard 990 transmitter rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 990 enclosure profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered via 4-20 mA current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC Targets) \u0026amp; Eddy-Current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe transmitter processes high-frequency eddy-current signals from a non-contacting probe across a calibrated 5.0-metre system length. Commissioning requires physical gap voltage validation across raw probe test terminals to ensure the sensor tip achieves a -10 VDC static bias voltage at the physical center of its linear span. Precise eddy-current probe scaling converts dynamic shaft displacement across targets as small as 9.5 mm (0.375 in) in diameter into a 4-20 mA current signal without phase distortion or amplitude degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What minimum target area is required for accurate displacement measurement?\u003c\/p\u003e\n\u003cp\u003eA: The transmitter requires a minimum observed target diameter of 9.5 mm (0.375 in) directly facing the probe tip to maintain specified probe scaling and linear current output.\u003c\/p\u003e\n\u003cp\u003eQ: How is loop power supplied to the module?\u003c\/p\u003e\n\u003cp\u003eA: Operating power is drawn directly from the 2-wire 4-20 mA loop circuit connected to the control system terminal interface.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting method does the -01 option code designate?\u003c\/p\u003e\n\u003cp\u003eA: The -01 mounting option specifies factory-installed 35 mm DIN rail clips attached to the base of the transmitter housing for rail snap-mounting.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transmitter module securely onto a grounded 35 mm DIN rail inside a protective field enclosure.\u003c\/li\u003e\n\u003cli\u003eAttach the proximity probe extension cable coaxial connector to the transmitter input interface, tightening hand-tight.\u003c\/li\u003e\n\u003cli\u003eValidate static DC gap voltage using a multimeter across test points, adjusting physical probe depth to achieve the -10 VDC target voltage.\u003c\/li\u003e\n\u003cli\u003eRoute 2-wire shielded twisted-pair cabling from the output terminals to the DCS or PLC analog input channel.\u003c\/li\u003e\n\u003cli\u003eGround the field cable shield at a single earth point on the cabinet earthing bar to mitigate ground loop noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43825045569626,"sku":"990-05-50-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/990-05-70-01-01_85b6f777-c55b-40ed-87a7-b654dd777ad7.png?v=1786436371","url":"https:\/\/www.spareoil.com\/products\/990-05-50-01-00-bently-nevada-990-2-wire-vibration-transmitter","provider":"SpareOil Automation","version":"1.0","type":"link"}