{"product_id":"aai841-s00-yokogawa-centum-vp-analog-input-output-module","title":"AAI841-S00 YOKOGAWA CENTUM VP Analog Input Output Module","description":"\u003ch2\u003eYOKOGAWA AAI841-S00 Analog Input Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA AAI841-S00 S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAAI841-S00\u003c\/strong\u003e Analog Input Output Module, operates as a dedicated hardware component for multi-channel current signal processing within CENTUM VP FIO subsystem platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI841-S00 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm x 132.5 mm x 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.6 A at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 % FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Loop Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AAI841-S00 architecture facilitates high-density signal acquisition for 4-20 mA HART loop protocol transmitters. Yokogawa engineers incorporate channel-to-channel isolation within this module to effectively suppress common-mode electrical noise and prevent ground-loop current propagation across the FIO node backplane. By providing dedicated cold junction compensation (CJC) pathing and internal range validation, the module ensures that digitized process variables remain consistent for the Field Control Station (FCS). Furthermore, the module supports dual-redundant configurations, allowing the control system to maintain loop continuity by switching to a secondary module during active diagnostic fault events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module accommodate voltage-based process signals?\u003c\/p\u003e\n\u003cp\u003eA: No, the AAI841-S00 is engineered specifically for 4-20 mA DC current loop inputs. Attempting to interface voltage transmitters requires external current-to-voltage conversion or the selection of an alternative voltage-capable module.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support HART pass-through communication?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is compatible with HART signal pass-through, enabling the Field Control Station to communicate directly with smart process transmitters for configuration and diagnostic parameter retrieval.\u003c\/p\u003e\n\u003cp\u003eQ: What action does the module take during a total power failure?\u003c\/p\u003e\n\u003cp\u003eA: Upon loss of 24 V DC power, the internal output drivers enter a high-impedance state, and the FIO node registers the channel status as \"bad\" to alert the control logic to the signal loss.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module into the designated slot within the FIO node cabinet, ensuring the backplane connector locks firmly into place. Maintain an ambient cabinet temperature between 0 and 50 deg C with adequate airflow. When routing field signal wires, utilize shielded, twisted-pair cabling to minimize inductive interference from neighboring power lines. Connect the cable shield drain wire to the instrument earth bus at the cabinet side to optimize electromagnetic compatibility. Avoid exceeding the maximum loop impedance specified for the transmitter to ensure current regulation within the 4-20 mA range. Finally, verify the cabinet supply voltage is stable at 24 V DC before seating the module to avoid surge damage to the input sensing circuits.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43572595294298,"sku":"AAI841-S00 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/166_bab2439d-9451-43fb-a6d8-fd67dc74c768.jpg?v=1782799356","url":"https:\/\/www.spareoil.com\/products\/aai841-s00-yokogawa-centum-vp-analog-input-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}