{"product_id":"aam51-s1-yokogawa-analog-output-module-centum-series-control-components","title":"AAM51-S1 YOKOGAWA Analog Output Module CENTUM Series Control Components","description":"\u003ch2\u003eYOKOGAWA AAM51-S1 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for precise signal conversion in CENTUM series platforms, the \u003cstrong\u003eYOKOGAWA AAM51-S1\u003c\/strong\u003e (\u003cstrong\u003eAAM51\u003c\/strong\u003e Current Voltage Output Module) provides direct physical execution of digital-to-analog signal translation for industrial field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAM51-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 mm x 120 mm x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 0-10 V DC (software selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLoop Connectivity and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe AAM51-S1 utilizes isolated output circuitry to maintain signal integrity across long-run field cabling. Each of the integrated output channels supports software-selectable ranges, enabling compatibility with 4-20 mA HART loop protocol architectures without requiring additional hardware bridges. Independent channel-to-channel isolation is implemented to mitigate ground loop currents and minimize the propagation of common-mode noise into the backplane communication bus. The module circuitry performs continuous internal verification of load resistance to detect open-circuit or short-circuit conditions, reporting faults directly to the controller for system-wide diagnostic monitoring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping during active process operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the hardware architecture supports hot-swappable installation within the standard Yokogawa I\/O rack. Ensure that field wiring is secured and that the software configuration is updated to recognize the replacement module upon insertion.\u003c\/p\u003e\n\u003cp\u003eQ: How is the output range configured for specific field devices?\u003c\/p\u003e\n\u003cp\u003eA: The output mode for each channel is software selectable. Configure the parameters via the engineering workstation associated with the CENTUM VP or CS3000 control environment to toggle between current (4-20 mA) and voltage (0-10 V) operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Seating:\u003c\/strong\u003e Verify that the I\/O rack backplane slot is free of debris. Align the module card edges with the guide rails before applying firm, even pressure to engage the backplane connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate cable shields at the designated common ground point on the I\/O rack chassis to maintain EMI\/RFI suppression effectiveness. Avoid routing analog signal cables parallel to high-voltage AC power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Resistance:\u003c\/strong\u003e Ensure that the total load resistance for current output channels does not exceed 750 Ohms to maintain output accuracy within specified tolerances. For voltage output applications, ensure the connected device impedance is at least 10 kOhms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain adequate clearance above and below the module within the rack to allow for convective airflow, ensuring ambient temperatures stay within the -20 deg C to +60 deg C range.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43660721946714,"sku":"AAM51 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/541._fda89ec0-319e-471a-a29f-939ae1cfe760.jpg?v=1784077585","url":"https:\/\/www.spareoil.com\/products\/aam51-s1-yokogawa-analog-output-module-centum-series-control-components","provider":"SpareOil Automation","version":"1.0","type":"link"}