{"product_id":"aav144-s00-yokogawa-fio-module-fast-global-shipping","title":"AAV144-S00 Yokogawa FIO Module | Fast Global Shipping","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAV144-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core high-density analog input component for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. This module captures analog voltage signals from field instruments—including pressure transmitters, flow meters, and temperature sensors—and converts them into high-fidelity digital data for the Field Control Unit (FCU). With 16 fully isolated channels, the AAV144-S00 eliminates ground loop interference and maintains signal stability in large-scale petrochemical, power, and utility facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New, Factory Sealed Original.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: AAV144 Series\u003c\/h3\u003e\n\u003cp\u003eYokogawa uses a structured coding system to define the functional limits and hardware revision of the AAV144 series.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAAV144:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase Series (Voltage Input Module, 16-channel).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard type for general industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic configuration (Non-enhanced).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways 0 (Standard hardware revision).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AAV144-S00 balances rapid data processing with extreme thermal resilience for mission-critical deployments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Full Channel-to-Channel Isolation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 5 V DC, -10 to +10 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2300 V AC (Field-to-System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 × 107.5 × 32.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 450 mA (5 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual isolation for each of the 16 channels prevents cross-talk and ensures that a localized electrical fault on one transmitter does not jeopardize the entire I\/O nest. This architecture maximizes uptime in safety-critical process loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Thermal Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard I\/O modules limited to 50°C, the AAV144-S00 operates reliably between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C and +80°C\u003c\/strong\u003e. This extended range allows installation in remote instrument enclosures or extreme climates without requiring expensive environmental control units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Loop Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 10 ms data update period enables the control system to react nearly instantaneously to process fluctuations. This speed proves vital for surge control in compressors and pressure regulation in volatile chemical reactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Marshaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 32.8 mm width allows engineers to pack high-density analog inputs into restricted cabinet spaces, reducing the total number of I\/O nodes and lowering infrastructure costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAV144-S00 accept 4-20 mA current signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Although the module natively measures voltage, you can monitor 4-20 mA signals by installing a precision 250-ohm shunt resistor across the input terminals to convert the current to a 1-5 V signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with the older CENTUM CS 3000 platform?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. The AAV144-S00 maintains full compatibility with both the legacy CENTUM CS 3000 and the current CENTUM VP platforms, facilitating seamless system expansions or hardware migrations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle a failed input signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AAV144-S00 includes continuous self-diagnostics and input monitoring. If a signal falls out of the designated range or a hardware fault occurs, the module triggers a system alarm to the Human Interface Station (HIS) for immediate technician intervention.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AAV144-S00 support redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. You can install these modules in a dual-redundant configuration on the FCU backplane to ensure continuous data acquisition even if one module requires replacement.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43155425427546,"sku":"AAV144-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/163._c74def60-0b6f-4811-af36-0d425acf0705.jpg?v=1774923747","url":"https:\/\/www.spareoil.com\/products\/aav144-s00-yokogawa-fio-module-fast-global-shipping","provider":"SpareOil Automation","version":"1.0","type":"link"}