{"product_id":"abb-1sap224100r0001-ac500-plc-profibus-dp-module","title":"ABB 1SAP224100R0001 AC500 PLC PROFIBUS DP Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB CI541-DP (1SAP224100R0001) serves as a high-versatility PROFIBUS DP slave interface module within the AC500 PLC ecosystem. This \"Mixed I\/O\" powerhouse combines analog and digital signal processing into a single decentralized node. It handles a diverse range of field signals, including Voltage (U), Current (I), and RTD temperature sensors, alongside standard 24V DC digital points. By integrating these functions into one compact unit, the CI541-DP reduces hardware footprints in distributed control architectures. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-speed data synchronization and robust fieldbus connectivity for your automation network.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI541-DP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1SAP224100R0001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP (Slave)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs (AI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels (U, I, RTD supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs (AO)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Channels (U, I supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs (DI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels (24V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs (DO)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels (24V DC, 0.5A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 kbps to 12 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.134 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e67.5 mm x 76 mm x 62 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–25°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe CI541-DP addresses the complexity of modern field installations by consolidating multiple signal types into a single PROFIBUS station.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Signal Consolidation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module eliminates the need for separate analog and digital expansion cards. By supporting Voltage, Current, and RTD inputs on the same device, it simplifies the mapping of complex process sensors like thermocouples and pressure transmitters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Bus Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI541-DP supports PROFIBUS baud rates up to 12 Mbps. This ensures that analog values and digital states reach the AC500 controller with minimal latency, which is essential for closed-loop PID control and safety interlocking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Interference Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated galvanic isolation separates the PROFIBUS network from the internal module logic. This protection prevents ground loops and electrical transients from disrupting communication, a vital feature for noisy environments like turbine halls and pump stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 67.5 mm width maximizes DIN-rail density. Despite its small profile, the module handles up to 0.5A per digital output, allowing it to actuate valves and relays directly without additional signal conditioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CI541-DP AI channels handle PT100 temperature sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 4 Analog Input channels support RTD configurations. You can wire PT100 or PT1000 sensors directly to the module to capture precise temperature data for process monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the digital output section require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must provide a 24V DC supply to power the module logic and the 8 digital output channels. Each output supports a load of 0.5A, sufficient for most industrial actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with non-ABB PROFIBUS Masters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a standard PROFIBUS DP Slave, the CI541-DP interfaces with any PLC or DCS controller that complies with the PROFIBUS DP protocol standard, though it is optimized for the ABB AC500 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIn what condition is the unit shipped?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee the CI541-DP 1SAP224100R0001 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It arrives in factory-sealed packing (Package Level 1: 84 x 72 x 71 mm) to ensure maximum reliability and longevity in the field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43199348506714,"sku":"CI541-DP 1SAP224100R0001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/442.jpg?v=1775813396","url":"https:\/\/www.spareoil.com\/products\/abb-1sap224100r0001-ac500-plc-profibus-dp-module","provider":"SpareOil Automation","version":"1.0","type":"link"}