{"product_id":"abb-gpu2000r-reg544-1sabb084621r0001-multifunction-generator-protection-relay","title":"ABB GPU2000R REG544 1SABB084621R0001 Multifunction Generator Protection Relay","description":"\u003ch2\u003eABB GPU2000R REG544 Generator Protection Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB GPU2000R REG544\u003c\/strong\u003e (\u003cstrong\u003e1SABB084621R0001\u003c\/strong\u003e) Generator Protection Unit serves as the primary multifunction relay utilized to execute fault detection and generator mitigation across power utility and industrial platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGPU2000R REG544\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm x 200 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (10-150 VAC\/VDC Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eTriple-processor system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003e27, 32R, 40, 50\/51, 50BF, 59, 81U\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus TCP\/RTU, DNP3, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Deterministic Networks and Firmware\u003c\/h3\u003e\n\u003cp\u003eThe GPU2000R REG544 platform employs a segmented triple-processor architecture to ensure deterministic network performance. By physically and logically isolating protection-critical logic from communication processing tasks, the unit maintains high-speed fault response times regardless of external communication loads via IEC 61850 or Modbus interfaces. The internal architecture supports firmware flash compatibility, allowing for on-site software updates to accommodate evolving grid synchronization requirements. The I\/O density scaling is managed through 8 programmable logic inputs and 6 configurable outputs, which facilitate precise interlocking sequences without compromising the cycle time of the main protection algorithms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the unit support hot-swapping while the generator is synchronized to the grid?\u003c\/p\u003e\n\u003cp\u003eA: No. The protection unit must be isolated from the current and voltage transformers (CT\/VT) and the control power supply before physical removal or replacement to prevent accidental tripping or damage to the secondary circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Is the communication port isolated from the analog measurement inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The device features galvanic isolation between the communication interfaces and the measurement circuitry to prevent high-voltage surges from the protection loops from propagating to the station bus or external monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the relay into a standard panel cutout using the provided mounting hardware. Ensure the chassis is bonded to the station earth grid using a low-impedance braided strap to manage transient EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT\/VT Wiring:\u003c\/strong\u003e Ensure secondary circuits of Current Transformers (CTs) are short-circuited via the test block before disconnecting the relay. Verify correct polarity for all phase current and voltage inputs to ensure accurate reverse power (32R) and excitation (40) function execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Cabling:\u003c\/strong\u003e Use shielded Ethernet cabling for IEC 61850 or Modbus TCP connections. Ensure the cable shield is grounded at the switch end to minimize the risk of ground loops between the protection unit and the network infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Testing:\u003c\/strong\u003e Perform a complete secondary injection test of the protective functions after installation. Verify that the output contact closure latency complies with the specific requirements of the circuit breaker trip circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42915717709914,"sku":"GPU2000R REG544","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/53_fe484401-0468-4b60-826c-4a16177494ed.jpg?v=1770863963","url":"https:\/\/www.spareoil.com\/products\/abb-gpu2000r-reg544-1sabb084621r0001-multifunction-generator-protection-relay","provider":"SpareOil Automation","version":"1.0","type":"link"}