{"product_id":"abb-innpm22-network-processor-modbus-ethernet-rs485","title":"ABB INNPM22 Network Processor | Modbus Ethernet RS485","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB INNPM22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-performance communication backbone for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSymphony Plus\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINFI 90\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHarmony Rack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. This Network Processor Module handles complex data exchange between controllers and field devices, ensuring seamless synchronization across distributed control systems (DCS). Specifically designed to work in conjunction with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINNIS21\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface, the INNPM22 executes multi-protocol communication including Ethernet, Modbus, and RS485. Its advanced processor architecture manages high-traffic industrial networks in power generation and petrochemical facilities, providing the sub-millisecond response times necessary for mission-critical automation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe INNPM22 integrates advanced processing power with broad protocol compatibility.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eINNPM22\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSymphony Plus \/ INFI 90 \/ Harmony Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet, Modbus RTU\/TCP, RS485, PROFIBUS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1 ms (IEC 60255 Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Supports 110–300 V DC\/AC wide input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61508 SIL3 Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 32 Digital Outputs (≤2 A per channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Low Latency Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe INNPM22 achieves a trip response time of ≤1 ms. This high-speed execution prevents equipment damage during electrical faults and ensures real-time stability for high-speed turbine control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module eliminates the need for external gateways. By supporting Ethernet, Modbus, and PROFIBUS natively, it allows the Symphony Plus system to interface directly with diverse third-party PLCs, drives, and smart field instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3 Functional Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard communication cards, the INNPM22 carries IEC 61508 SIL3 certification. This validates the module for use in Safety Instrumented Systems (SIS) where a failure could lead to environmental or human risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Self-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module identifies internal hardware faults and network bottlenecks instantly via LED fault codes. This allows maintenance teams to bypass complex software debugging and go directly to the point of failure, drastically reducing Mean Time To Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe INNPM22 supports online replacement. Technicians swap modules while the rack remains powered, ensuring zero downtime for continuous processes in oil refineries and power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e100% Brand New Condition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe supply only original, factory-sealed ABB units. This ensures the 24V DC power circuitry and 32-bit processing logic meet original performance benchmarks, avoiding the reliability risks associated with discontinued or \"refurbished\" hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the INNPM22 a direct replacement for older Symphony network modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The INNPM22 is designed for the INNIS21 interface and maintains backward compatibility with legacy INFI 90 and Harmony Rack architectures, making it an ideal choice for system modernization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle fault detection within the DCS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe INNPM22 features built-in self-diagnostics. It monitors its own internal health and communication traffic, broadcasting status updates to the HMI and displaying specific fault codes via the faceplate LEDs for immediate local troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a specific mounting environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe INNPM22 is an IP20-rated module designed for rack mounting. For industrial environments, you must install it within a protective enclosure that manages ambient dust and prevents accidental contact with live circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the INNPM22 drive digital outputs directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. This module supports up to 32 digital outputs with a capacity of up to 2 A per channel, allowing it to trigger auxiliary relays or status indicators directly from the network processor logic.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43173396742234,"sku":"INNPM22","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/363.1_b74fa4e3-fe4c-47df-a302-a35f7414e322.jpg?v=1775182686","url":"https:\/\/www.spareoil.com\/products\/abb-innpm22-network-processor-modbus-ethernet-rs485","provider":"SpareOil Automation","version":"1.0","type":"link"}