{"product_id":"abb-rec650-1mrk008514-ab-relion-650-bay-control-ied-protection-module","title":"ABB REC650 1MRK008514-AB Relion 650 Bay Control IED Protection Module","description":"\u003ch2\u003eABB REC650 Relion 650 Bay Control IED\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 1MRK008514-AB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eREC650\u003c\/strong\u003e Bay Control IED, operates as a dedicated hardware component for substation management and switchgear control within high-voltage automation networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eREC650 (1MRK008514-AB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e270 mm x 180 mm x 225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e48-125 VDC or 110-250 VDC \/ 100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eBay Control \u0026amp; Protection IED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eClass 0.5 (Current\/Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe REC650 utilizes high-speed internal bus architecture to manage deterministic data exchange between the bay control logic and the substation communication network. To ensure operational integrity, the module performs real-time verification of I\/O states, minimizing latency in breaker interlocking and protection commands. Proper firmware flash compatibility is required when upgrading substation automation environments to ensure the IED correctly maps IEC 61850 data sets to the existing system bus. The module supports robust PRP and HSR protocols, allowing for seamless integration into high-availability communication rings without compromising control loop determinism.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the REC650 support hot-swapping of I\/O modules during operation?\u003c\/p\u003e\n\u003cp\u003eA: No, the REC650 IED hardware does not support hot-swapping of internal I\/O modules. The device must be de-energized and disconnected from the substation communication network prior to any internal module maintenance or replacement to prevent electrical faults.\u003c\/p\u003e\n\u003cp\u003eQ: Is the unit compatible with both PRP and HSR redundancy protocols?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the REC650 supports both Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) protocols. These must be enabled and configured via the device settings to ensure zero-packet-loss communication in the event of a network link failure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the REC650 chassis is connected to the substation earth bus using a low-impedance conductor to maintain EMC compliance.\u003c\/li\u003e\n\u003cli\u003eVerify that the auxiliary power supply input aligns with the specific module voltage rating before applying power.\u003c\/li\u003e\n\u003cli\u003eUse shielded fiber-optic or twisted-pair cabling for Ethernet communication ports to minimize interference from nearby high-voltage switchgear.\u003c\/li\u003e\n\u003cli\u003eSecure the module within the 6U rack housing and tighten all mounting fasteners to prevent mechanical vibration under fault conditions.\u003c\/li\u003e\n\u003cli\u003ePerform a full system-level diagnostic and functional test, including interlocking logic validation, before energizing the controlled primary switchgear.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42915318988890,"sku":"REC650","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/44_f84c49fd-4262-4efc-bde1-c33de49d03d8.jpg?v=1770860619","url":"https:\/\/www.spareoil.com\/products\/abb-rec650-1mrk008514-ab-relion-650-bay-control-ied-protection-module","provider":"SpareOil Automation","version":"1.0","type":"link"}