{"product_id":"adv151-p13-yokogawa-centum-series-datasheet-technical-manual","title":"ADV151-P13 Yokogawa CENTUM Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eYokogawa ADV151-P13 CENTUM Series Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-P13\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete signal processing and field network data translation within CENTUM VP and CS3000 FIO platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P13 (Style S2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (Net module weight; gross shipping weight is 1.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 40 mm x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Storage: -40 to +85 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC @ 1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Architecture\u003c\/td\u003e\n\u003ctd\u003eMultipoint discrete tracking points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Protocol\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP (Redundancy supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps Ethernet (Full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CS3000 FIO Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Diagnostics\u003c\/td\u003e\n\u003ctd\u003eIntegrated front-panel LEDs (Communication, Error, Module Health)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ADV151-P13 utilizes high-integrity channel-to-channel isolation circuits to block high-voltage common-mode transients from corrupting downstream logic subassemblies. To prevent signal distortion over extended distribution layouts, the hardware architecture implements an isolated 4-20 mA HART loop protocol routing topology alongside the base digital acquisition pathways. The onboard processing matrix filters field contact chatter automatically, standardizing discrete input states before translating the data packets over the full-duplex 100 Mbps Vnet\/IP busway.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle bus switchover delays when operating in a dual-redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: The hardware links directly into parallel backplane channels on the FIO nest. In the event of a primary processor or communication fault, the system triggers an automated switchover sequence to the secondary card, maintaining active status loops with negligible network lag.\u003c\/p\u003e\n\u003cp\u003eQ: What are the lifecycle compatibility restrictions regarding legacy Style S2 ADV151-P13 hardware?\u003c\/p\u003e\n\u003cp\u003eA: The ADV151-P13 model configuration is discontinued by the manufacturer. Existing installations requiring total card replacement or scaling updates use the direct functional successor assembly labeled as part number ADV151-P63\/D5A00.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for single module deployments under live system conditions?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is strictly limited to dual-redundant configurations where a secondary card is actively maintaining data telemetry. Pulling a single-channel card while energized breaks all associated digital input loops instantly and flags an error register at the controller terminal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFIO Slot Interlocking:\u003c\/strong\u003e Position the circuit board alignment wings within the guide rails of the designated CENTUM FIO nest slot. Push firmly to ensure complete engagement of the rear edge connector block, then tighten the captive locking screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface Shielding:\u003c\/strong\u003e Ground all multi-conductor field input shields exclusively at the Marshalling panel instrumentation ground bus bar. Never ground both ends of the shielding braid to prevent high-frequency current loops from introducing noise jitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Isolation:\u003c\/strong\u003e Route the low-voltage discrete signal paths and Vnet\/IP network connections through dedicated wiring ducts separate from any high-amperage AC utility feeds, motor supply links, or high-power inductive switching rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Convection Clearances:\u003c\/strong\u003e Leave the manufacturer-specified ventilation pathways open around the FIO chassis housing. Restricting airflow around this 1.2 A rated unit causes localized heat build-up, exceeding the 60 deg C operating threshold and degrading conversion component lifespans.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43497839624282,"sku":"ADV151-P13","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/173_a70b86dd-cbb6-41a8-ae3a-495f9cb690fc.jpg?v=1781511981","url":"https:\/\/www.spareoil.com\/products\/adv151-p13-yokogawa-centum-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}