{"product_id":"adv169-p00-st6-yokogawa-digital-input-module","title":"ADV169-P00 ST6 Yokogawa Digital Input Module","description":"\u003ch2\u003eYokogawa ADV169-P00 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in CENTUM VP and ST6 automation systems, the \u003cstrong\u003eYokogawa ADV169-P00\u003c\/strong\u003e (\u003cstrong\u003eADV169\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric suffix codes define the exact hardware standard and functional profile of this input module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eADV169: Base configuration designating a 64-channel isolated digital input module with common minus architecture grouped every 16 channels.\u003c\/li\u003e\n\u003cli\u003e-P: Standard type hardware interface for generic discrete level parsing.\u003c\/li\u003e\n\u003cli\u003e0: Fixed placeholder component designated as always zero.\u003c\/li\u003e\n\u003cli\u003e0: Basic option variant specifying standard environment configuration parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV169-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 10.7 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64 isolated digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 20 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC between field inputs and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface\u003c\/td\u003e\n\u003ctd\u003eKS9 dedicated execution assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDistributed Process Integration\u003c\/h3\u003e\n\u003cp\u003eThe module manages isolated contact scanning via internal optocouplers, establishing channel-to-channel isolation zones across 64 discrete inputs grouped with a common minus bus every 16 channels. This architecture directly processes logic transitions from field sensors while blocking inductive voltage surges from propagating into the system backplane. Field loop signals undergo digital conditioning to ensure reliable state changes within a deterministic time window of less than or equal to 8 ms. Status verification occurs via integrated front-panel LEDs displaying the active configuration of individual physical points.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary constraints when executing a hot-swap operation on the ADV169-P00 module?\u003c\/p\u003e\n\u003cp\u003eA: The online swap requires the system backplane to remain powered while you extract the module. You must disconnect the KS9 multi-pin terminal connector first to ensure zero active loop current passes through the alignment pins during mechanical disengagement.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module directly process discrete 24 VDC industrial signals from field switches?\u003c\/p\u003e\n\u003cp\u003eA: No. The input circuitry is specifically tuned for a rated input voltage of 5 VDC. Exposing the channels to 24 VDC logic levels will overload the internal input resistors and cause permanent thermal breakdown of the optocouplers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Ground Alignment\u003c\/strong\u003e: Verify the FIO rack ground bar bonds directly to the primary instrument earth before sliding the unit into place to guarantee functional isolation performance up to the 2 kV AC threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Grouping Constraints\u003c\/strong\u003e: Structure the external terminal terminal blocks to reflect the 16-channel common minus design layout, preventing unintended cross-talk loops between separate field power references.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Termination Security\u003c\/strong\u003e: Seat the KS9 dedicated interface cable firmly into the front interface socket, tightening the integrated retaining screws to preserve fixed contact resistance metrics under vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Spacing Execution\u003c\/strong\u003e: Maintain standard convection clearance vectors around the I\/O nest to prevent stagnant hot air zones when operating near the upper ambient limit of 70 deg C.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43664852058202,"sku":"ADV169-P00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/551._81e7e94e-4a72-416e-a058-2ef87c0c0d81.jpg?v=1784167864","url":"https:\/\/www.spareoil.com\/products\/adv169-p00-st6-yokogawa-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}