{"product_id":"adv551-p63-s2-yokogawa-centum-vp-output-module","title":"ADV551-P63 S2 Yokogawa CENTUM VP Output Module","description":"\u003ch2\u003eYokogawa ADV551-P63 S2 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV551-P63 S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete actuation driving within CENTUM VP and ProSafe-RS control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (ADV551):\u003c\/strong\u003e Digital Output Module featuring 32 isolated output channels operating at 24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction Suffix (-P):\u003c\/strong\u003e Includes pulse width output and time-proportional output functionality for modulated field element control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Suffix (6):\u003c\/strong\u003e Equips status display LEDs on the front panel and indicates no explosion protection rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Suffix (3):\u003c\/strong\u003e Includes ISA Standard G3 conformal coating and an extended operating temperature rating (-20 to 70 deg C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStyle Code (S2):\u003c\/strong\u003e Hardware circuit design revision level denoting specific component and backplane firmware baseline compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P63 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (2.0 kg shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa I\/O module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA max at 5 VDC, 60 mA max at external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels, current sink format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (100 mA\/channel max at 26.4 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Withstand\u003c\/td\u003e\n\u003ctd\u003e2000 VAC between signal and system for 1 minute; 500 VAC between commons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Functions\u003c\/td\u003e\n\u003ctd\u003eON\/OFF status, pulse width output, time-proportional output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop \u0026amp; Fieldbus Connectivity Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe ADV551-P63 S2 provides high-density discrete signal delivery to control valves, solenoid relays, and alarm indicators while operating alongside analog I\/O cards within CENTUM CS 3000 \/ VP node architectures. Integrated pulse-width modulation algorithms allow fine-tuned temporal control over solenoid manifolds without routing processing cycles back to the main CPU module. Ground loop current is decoupled via 2000 VAC optic\/galvanic barriers, preventing electrical noise propagation into adjacent 4-20 mA HART instrumentation loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV551-P63 S2 module support hot-swap replacement in active systems?\u003c\/p\u003e\n\u003cp\u003eA: Yes, online replacement is supported when mounted in redundant I\/O nests or standard active node slots without interrupting system backplane communication.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum sink current allowable per individual output channel?\u003c\/p\u003e\n\u003cp\u003eA: Each channel supports a maximum current sink rating of 100 mA at 26.4 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How is the common return path partitioned across the 32 output channels?\u003c\/p\u003e\n\u003cp\u003eA: Common connections are split every 16 channels on the common minus (-) side, providing 500 VAC withstand voltage between distinct common groups.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eField Supply Isolation: De-energize external 24 VDC field load power supplies prior to connecting field wiring harnesses to prevent accidental terminal shorting.\u003c\/li\u003e\n\u003cli\u003eShield \u0026amp; Grounding Setup: Connect signal cable shields directly to the cabinet instrumentation ground bar to ensure optimal noise immunity and surge protection.\u003c\/li\u003e\n\u003cli\u003eModule Insertion: Slide the card along node guide rails until the backplane connector locks in place, then tighten upper and lower panel thumbscrews.\u003c\/li\u003e\n\u003cli\u003eConductor Separation: Route 24 VDC digital output wiring through cable ducts separate from AC power conduits and high-frequency communication trunks.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859597295706,"sku":"ADV551-P63-S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/568._dc50e8df-8de4-4bba-ab54-8fb860f3a9b2.jpg?v=1787018529","url":"https:\/\/www.spareoil.com\/products\/adv551-p63-s2-yokogawa-centum-vp-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}