{"product_id":"adv569-p00-yokogawa-centum-vp-64-channel-digital-output-module","title":"ADV569-P00 Yokogawa CENTUM VP 64 Channel Digital Output Module","description":"\u003ch2\u003eYokogawa ADV569-P00 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV569-P00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV569\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for high-density discrete load switching and time-proportional pulse control within CENTUM VP control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Implication\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV569\u003c\/td\u003e\n\u003ctd\u003eBase Hardware Model\u003c\/td\u003e\n\u003ctd\u003eHigh-density digital output module for compatible ST7 terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eFunction Option\u003c\/td\u003e\n\u003ctd\u003eIntegrates pulse width output and time-proportional control logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eReserved Code\u003c\/td\u003e\n\u003ctd\u003eStandard factory designation (always 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eType Option\u003c\/td\u003e\n\u003ctd\u003eBasic hardware specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV569-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg Net \/ 2.0 kg Shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 100 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels (isolated, common minus side every 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sink, 24 VDC switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 16 ms typical (pulse width adjustable 8 ms to 7200 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Circuits\u003c\/td\u003e\n\u003ctd\u003eShort-circuit and overload protection built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Integration\u003c\/td\u003e\n\u003ctd\u003eConnects via ESB optical bus to Field Control Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Output Switching\u003c\/h3\u003e\n\u003cp\u003eThe module interface handles high-density output processing across 64 discrete channels, using common negative side isolation grouped per 16 channels to isolate external load loops. It integrates directly with Field Control Units over optical ESB bus backplanes, delivering precise signal actuation for solenoid valves, motor starter interlocks, and alarm annunciators. Internal optocoupler hardware ensures channel-to-system isolation, preventing external field transients from disturbing internal process control logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can an ADV569-P00 module be replaced online without disrupting the node?\u003c\/p\u003e\n\u003cp\u003eA: Yes. You can remove and replace the ADV569-P00 under live system power without de-energizing the baseplate or interrupting signal execution on adjacent modules.\u003c\/p\u003e\n\u003cp\u003eQ: What functionality does the \"-P\" suffix add to the digital outputs?\u003c\/p\u003e\n\u003cp\u003eA: The \"-P\" suffix enables onboard pulse width output and time-proportional output processing, allowing software control loops to adjust drive signal duration from 8 ms to 7200 s directly at the hardware layer.\u003c\/p\u003e\n\u003cp\u003eQ: How is field-side electrical isolation structured across the output channels?\u003c\/p\u003e\n\u003cp\u003eA: Channel isolation is arranged with common minus terminals per 16 channels, providing galvanic separation between channel banks and logic circuits to block loop fault propagation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Slot Insertion:\u003c\/strong\u003e Seat the module firmly into the targeted baseplate slot until upper and lower retaining clips click into place. Confirm full backplane connector engagement before applying external 24 VDC power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Shielding and Earth Strapping:\u003c\/strong\u003e Attach the cabinet metal housing to the plant safety earth copper bar via a dedicated low-impedance ground wire. Ground signal cable shields at a single point to eliminate ground potential loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Load Wiring Separation:\u003c\/strong\u003e Lay 24 VDC field output lines in separate wire channels away from high-voltage AC cables and sensitive analog measurement lines to suppress electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859804094554,"sku":"ADV569-P00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/38_20b83a4b-acac-4093-be69-1794467ec283.jpg?v=1787025114","url":"https:\/\/www.spareoil.com\/products\/adv569-p00-yokogawa-centum-vp-64-channel-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}