{"product_id":"adv569-p50-yokogawa-64-channel-digital-output-module","title":"ADV569-P50 Yokogawa 64-Channel Digital Output Module","description":"\u003ch2\u003eYokogawa ADV569-P50 CENTUM VP Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density transistor switching in CENTUM VP control systems, the \u003cstrong\u003eYokogawa ADV569-P50\u003c\/strong\u003e (\u003cstrong\u003eADV569\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution across 64 isolated output channels. The hardware executes current-sink transistor switching to drive external status indicators, solenoids, and interlock relays. It processes discrete commands with an integrated time-proportional control algorithm and single-shot pulse output capability. Channel isolation grouped in 16-channel common negative-side banks protects backplane communication circuits against field-side electrical interference.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV569-P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 127.2 x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.4 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor contact (current sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon minus side every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e2 VDC or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e16 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eField Control Unit (FCU) cabinet rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Loop \u0026amp; Signal Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates robust channel-to-channel isolation architecture designed for 4-20 mA HART loop protocol environments and high-density digital field wiring. Common-mode noise suppression is enforced via galvanic isolation across each 16-channel negative-side bank, preventing ground loop potential differences from corrupting backplane signaling. Integrated drive circuits support pulse-width modulation and time-proportioning output routines directly on the module hardware, offloading processing overhead from the primary Field Control Unit CPU during complex process control operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the dual-redundancy configuration operate on the ADV569-P50?\u003c\/p\u003e\n\u003cp\u003eA: Dual redundancy requires two ADV569-P50 modules installed in paired slots on a compatible CENTUM VP terminal board. The system continuously validates channel states; upon detection of a hardware fault on the active card, execution switches to the standby card within the system execution cycle to maintain uninterruptible load control.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions must be taken regarding output load current limits?\u003c\/p\u003e\n\u003cp\u003eA: Each channel accommodates a maximum continuous load current of 100 mA at 30 VDC. Exceeding this limit triggers thermal degradation of the output transistors. External inductive loads require inductive suppression diodes installed across the field device terminals to prevent reverse voltage spikes from damaging the internal switching matrix.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the rack power supply unit prior to inserting or removing the module from the node base plate to prevent backplane pin damage.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edge connectors with the targeted slot guide rails inside the Field Control Unit or extension node unit.\u003c\/li\u003e\n\u003cli\u003ePush the module firmly into the slot until the top and bottom retaining latches click securely into place.\u003c\/li\u003e\n\u003cli\u003eDress field wiring cables along designated cable trays, ensuring signal wires maintain a minimum separation distance of 200 mm from high-voltage AC power lines.\u003c\/li\u003e\n\u003cli\u003eTerminate the shield braid of field cables to the cabinet grounding bar using a low-impedance ground clamp. Ensure a single-point connection to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify that the total load current per 16-channel bank does not exceed thermal dissipation thresholds before energizing the 24 VDC loop field supply.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43865921552474,"sku":"ADV569-P50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/833.jpg?v=1787101160","url":"https:\/\/www.spareoil.com\/products\/adv569-p50-yokogawa-64-channel-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}