{"product_id":"advant-lan-interface-module-abb-ci513-3bse000435r1","title":"Advant LAN Interface Module ABB CI513 3BSE000435R1","description":"\u003ch2\u003eABB CI513 LAN Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for MasterBus 300 (MB300) network integration in Advant Controller 400 series systems, the \u003cstrong\u003eABB CI513\u003c\/strong\u003e (\u003cstrong\u003e3BSE000435R1\u003c\/strong\u003e) operates as a dedicated hardware component for deterministic IEEE 802.3 Ethernet communication within ABB distributed control environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI513\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e234 x 18 x 108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 Ethernet (MB300)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eAdvant AC450 \/ AC460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMasterBus 300 Deterministic Network Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CI513 serves as the primary bridge for peer-to-peer communication between AC400 series controllers and higher-level systems like 800xA. Unlike standard commercial Ethernet, the CI513 implementation is tuned for MB300 protocol requirements, providing the necessary determinism for time-critical process data exchange. The module incorporates robust galvanic isolation to safeguard controller logic against network-borne surges and electromagnetic interference (EMI). Its integration into the subrack backplane allows for efficient data routing while maintaining the integrity of the controller's internal bus communication velocity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CI513 support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CI513 is designed for modular subrack systems and supports hot-swapping. This allows for the removal and replacement of the module without requiring a full system shutdown, facilitating maintenance in high-availability environments.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 10 Mbps data transmission rate a limitation for large-scale data transfer?\u003c\/p\u003e\n\u003cp\u003eA: The 10 Mbps rate is fixed to align with the timing and determinism requirements of the MasterBus 300 protocol. While not comparable to modern high-speed office Ethernet, this rate ensures that process data packets maintain priority and predictable delivery times necessary for industrial control stability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Mounting\u003c\/strong\u003e: Align the CI513 with the subrack guide rails and insert the module until the backplane connector is fully engaged. Secure the module using the front-panel locking screws to ensure consistent chassis ground connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cabling\u003c\/strong\u003e: Use high-quality, shielded Ethernet cabling compatible with the MasterBus 300 physical layer specifications. Terminate shields properly at the cabinet ground bus bar to prevent common-mode noise injection into the controller backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Validation\u003c\/strong\u003e: Upon power-up, observe the front-panel LED indicators. A stable 'Run' status combined with an active 'Link' LED confirms the module has successfully established network communication. If the 'System Fault' LED illuminates, verify the module seating and check for bus-level communication errors via the engineering workstation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance\u003c\/strong\u003e: Regularly inspect communication ports for physical wear. Since the module features galvanic isolation, minimal maintenance is required; however, ensure environmental conditions remain within the specified temperature and humidity ranges to prevent long-term component degradation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42915252174938,"sku":"CI513","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/40_99740c52-ea58-4451-83ca-06d17308375f.jpg?v=1770859208","url":"https:\/\/www.spareoil.com\/products\/advant-lan-interface-module-abb-ci513-3bse000435r1","provider":"SpareOil Automation","version":"1.0","type":"link"}