{"product_id":"aip501-s1-yokogawa-centum-vp-vnet-input-module","title":"AIP501-S1 Yokogawa CENTUM VP Vnet Input Module","description":"\u003ch2\u003eYokogawa AIP501-S1 Vnet Coupler Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed signal interface execution in CENTUM VP, CS 1000, and CS 3000 control systems, the \u003cstrong\u003eYokogawa AIP501-S1\u003c\/strong\u003e (\u003cstrong\u003eAIP501\u003c\/strong\u003e Universal Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIP501\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eUniversal Analog Input Module (16-Channel, VNET format)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-S1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware Style\u003c\/td\u003e\n\u003ctd\u003eStyle 1 Revision \/ Specific Mounting Circuit Variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP501-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg (Net, 1.05 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 25.4 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power load via VNET bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 1000, CS 3000 Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 universal analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, RTD, Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% (Voltage\/Current), +\/- 0.05% (RTD\/TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms cycle time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eHART protocol supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between field loops and backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AIP501-S1 input module routes multi-variable field instrumentation data across VNET real-time control networks. Integrated signal condition circuits process 4-20 mA HART loop protocol transmitters along with direct millivolt and resistance sensor inputs without requiring external signal converters. Cold junction compensation (CJC) circuitry embedded within the terminal path maintains precision temperature scaling for thermocouple pairs, while channel-to-channel isolation suppresses common-mode noise across industrial grounding points.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the AIP501-S1 module support direct connection of RTD and thermocouple sensors without external transmitters?\u003c\/p\u003e\n\u003cp\u003eA: Yes, internal signal conditioning circuitry scales RTD resistance and thermocouple millivolt signals directly across its 16 universal input channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the AIP501-S1 handle HART digital communication superimposed on analog loops?\u003c\/p\u003e\n\u003cp\u003eA: Internal pass-through filters extract HART digital FSK signals from 4-20 mA current loops, forwarding field device diagnostics to the CENTUM system management layer.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the AIP501-S1 module vertically into the designated VNET rack slot until the backplane bus card-edge connectors click firmly into place. Tighten top and bottom panel thumb screws to secure structural alignment and maintain frame ground continuity. Route analog signal field wiring through shielded twisted-pair cables, keeping sensor runs physically separated from high-current AC power conductors. Ground cable drain shields at a single point on the cabinet grounding bar to eliminate ground loops and ensure signal integrity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43838759436378,"sku":"AIP501","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/807..jpg?v=1786601049","url":"https:\/\/www.spareoil.com\/products\/aip501-s1-yokogawa-centum-vp-vnet-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}