{"product_id":"allen-bradley-1404-m405a-dnt-devicenet-power-meter-brand-new","title":"Allen-Bradley 1404-M405A-DNT DeviceNet Power Meter Brand New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1404-M405A-DNT serves as the primary processing core and intelligence unit for the Powermonitor 3000 sub-metering system. This panel-mounted master module delivers comprehensive, revenue-grade diagnostics across three-phase electrical networks by measuring true RMS voltage, current, real\/reactive\/apparent power parameters, and total consumption metrics. Featuring integrated DeviceNet and RS-485 communication protocols, the module streams real-time power quality analytics directly to programmable logic controllers (PLCs) and facility-wide SCADA monitoring stations. We provide this electrical component as a 100% brand new, original factory unit to ensure precise diagnostic accuracy and immediate plant integration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following comprehensive table outlines the electrical boundaries, input tolerances, and functional capacities of the 1404-M405A-DNT master module:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1404-M405A-DNT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowermonitor 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original Factory Packaging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaster Power Monitoring Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Network Connectivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet and RS-485 Networks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Power Input Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120-240 V AC (50\/60 Hz) or 125-250 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Control Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 VA Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e480 V AC Line-to-Line\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input Detection Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20-600 V AC Line-to-Line\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBurden on Voltage Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 0.5 VA Per Single Phase Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Current Transformer Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A AC Secondary Output (External CT Required)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBurden on Current Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 0.5 VA Per Single Phase Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Digital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Optically Isolated Inputs (18-30 V DC, 6 mA at 24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Relay Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Form C Relays (Rated at 240 V AC, 2 A Resistive Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Ambient Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 degrees C (32 to 131 degrees F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Module Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190 x 115 x 145 mm (7.48 x 4.53 x 5.71 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Module Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.42 kg (3.13 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevenue-Grade Power Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module processes raw analog phase waves through internal high-speed DSP circuits to deliver 1% revenue-grade metering precision. This level of precision eliminates estimation errors, allowing facility managers to utilize data safely for utility sub-metering and internal cost-center billing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutonomous Automated Load Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour integrated Form C mechanical relays allow the module to execute local load-shedding commands without waiting for a PLC intervention loop. When demand spikes past pre-set thresholds, the internal contacts drop out instantly to disconnect non-essential downstream motors or heating banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Transient Protection for Digital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe four onboard digital inputs feature 24V DC optical isolation circuits. This barrier blocks industrial high-voltage switching surges and inductive line noise, preventing field-side voltage spikes from bleeding backward into the sensitive core monitoring microprocessors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual AC\/DC Universal Control Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flexible power stage accepts a broad input array spanning 120-240V AC or 125-250V DC. This adaptability ensures uninterrupted instrumentation logging even when severe line brownouts degrade standard facility AC supply networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Integration into Automation Tags:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe native DeviceNet network interface permits automatic hardware mapping into Logix memory structures. Engineers pull voltage imbalances, total harmonic distortion values, and power factor logs into PLC rungs without writing convoluted ASCII data parsers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I wire the 1404-M405A-DNT current sensing lines directly to the main high-voltage busbars?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. You must never connect high-voltage power lines directly to the current inputs of this module. The 1404-M405A-DNT requires standard external current transformers (CTs) with a nominal 5 A AC secondary output to reduce line currents to safe operational sensing thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit retain stored energy logs and historical peak demand data during an absolute power outage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe master module utilizes internal non-volatile data logging sectors. It saves critical billing data, event history records, and hardware calibration tables permanently without relying on external lithium batteries or continuous control power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the low burden rating on the voltage and current transformer inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module exhibits a tiny burden rating of less than 0.5 VA per input phase. This low burden ensures that the monitoring unit draws virtually zero power from the measurement loop, preventing the meter itself from skewing or distorting downstream loop voltage and current signals. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43386954580058,"sku":"1404-M405A-DNT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/52._dc40ce45-d1ff-4f07-992a-0e88ad5340fe.jpg?v=1779069856","url":"https:\/\/www.spareoil.com\/products\/allen-bradley-1404-m405a-dnt-devicenet-power-meter-brand-new","provider":"SpareOil Automation","version":"1.0","type":"link"}