{"product_id":"allen-bradley-1440-tb-a-dynamic-measurement-base-new","title":"Allen Bradley 1440-TB-A Dynamic Measurement Base New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen Bradley 1440-TB-A functions as a specialized terminal base unit engineered exclusively for the XM Series machinery protection ecosystem. This component establishes the physical and electrical interface between field-installed machinery sensors (such as accelerometers, eddy current proximity probes, and temperature transducers) and active monitoring modules like the XM-12 dynamic eccentricity module. By separating field wiring from the processing electronics, this unit enables clean wire termination and rapid module hot-swapping. We supply this product as a 100% brand-new, factory-sealed unit to guarantee reliable signal conductivity and long-term installation stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXM Series Accessories\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1440-TB-A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Factory Sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Base Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew-clamp Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Wire Sizes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 to 22 AWG Solid or Stranded Copper Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley XM Series (e.g., XM-12, 1440-VST Modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Sensor Wiring Interface and Backplane Path\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 Degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 Degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Humidity Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 percent to 95 percent Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Base Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.31 lbs (inclusive of heavy industrial protective packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CSA, CE Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Maintenance and Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe independent architecture separates the field wiring terminals from the active instrumentation module. This means maintenance technicians can unseat and replace a faulty XM processing module without disconnecting a single field sensor wire, minimizing machinery protection downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecures Critical Sensor Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeavy-duty screw-clamp terminations lock 14-22 AWG field conductors firmly in place. This mechanism prevents wire back-outs and intermittent electrical resistance shifts caused by continuous, high-amplitude vibrations near heavy rotating turbines or industrial compressors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimizes High-Density Enclosure Layouts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim DIN-rail form factor allows quick snap-on mounting inside standard electrical cabinets. This compact layout maximizes cross-terminal density, allowing panel builders to aggregate signals from multiple vibration sensors into a narrow cabinet footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintains High Signal Truth:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal routing architecture maintains continuous electrical shield tracking through the termination blocks. This layout isolates delicate micro-volt instrumentation signals from neighboring high-amperage power tracks, ensuring raw sensor data reaches the processing logic without electromagnetic corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1440-TB-A operate as a standalone measuring tool or controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1440-TB-A serves strictly as a passive wiring terminal base and mechanical mounting receptacle. It contains no processing intelligence or communication chips. It requires a compatible active XM Series processing module (such as a 1440-VST vibration module or XM-12 eccentricity card) to read sensor data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of wiring styles can I use with these screw-clamp blocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe termination blocks accept both solid and stranded copper wires ranging from 14 to 22 AWG. If using stranded wiring in high-vibration zones near turbines and pumps, terminate the wire ends with insulated bootlace ferrules before clamping down the screws to prevent conductor fraying.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this terminal base support hot-swapping of active XM modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can install or remove compatible Allen Bradley XM modules from this terminal base while the chassis remains powered up. The design ensures the ground paths engage first and disengage last, shielding your brand-new system from static and voltage transients during hot-swap maintenance windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43404027658330,"sku":"1440-TB-A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/108.1_95b14b9e-99cf-433d-895f-0e357c3cac96.jpg?v=1779413324","url":"https:\/\/www.spareoil.com\/products\/allen-bradley-1440-tb-a-dynamic-measurement-base-new","provider":"SpareOil Automation","version":"1.0","type":"link"}