{"product_id":"analog-input-brand-new-original-yokogawa-sdv144-s13-b4d10","title":"Analog Input | Brand New Original | Yokogawa SDV144-S13\/B4D10","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SDV144-S13\/B4D10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog voltage acquisition module for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems. This module captures 16 channels of isolated voltage signals from field instruments, providing the critical data link between field sensors and the control processor. Engineers deploy the SDV144-S13 in demanding oil \u0026amp; gas, chemical, and power generation environments where high-speed signal processing (10ms update) and robust channel-to-channel isolation are mandatory for operational safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: SDV144 Series\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes specific coding to define the hardware revision and environmental specifications of the SDV144 series.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSDV144\u003c\/strong\u003e: Isolated Analog Voltage Input Module (16-Channel).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S\u003c\/strong\u003e: Standard type for FIO systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Style code (indicates specific hardware generation\/components).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3\u003c\/strong\u003e: Enhanced durability revision with specific temperature or coating standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB4D10\u003c\/strong\u003e: Option code for integrated dual-redundant pressure clamp terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe SDV144-S13\/B4D10 delivers high-fidelity signal conversion and extreme isolation for sensitive control loops.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 V to +10 V, 1 to 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit High Precision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Channel-to-system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-Redundant Pressure Clamp (\/B4D10)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 × 107.5 × 32.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Loop Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10ms update period enables the control system to react instantly to rapid process fluctuations. This speed ensures safety and stability in dynamic pressure and flow control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Ground Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull channel-to-channel isolation prevents electrical noise and ground potential differences from contaminating adjacent signal loops. This architecture ensures that a single field device fault does not compromise the integrity of the remaining 15 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \/B4D10 option integrates dual-redundant pressure clamp terminals directly into the interface. This design saves significant cabinet space compared to traditional marshaling setups and provides a vibration-proof connection that outperforms standard screw terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Self-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module executes continuous internal health checks. It monitors input signal health and internal hardware status, reporting faults to the Human Interface Station (HIS) immediately to facilitate proactive maintenance and prevent unplanned shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SDV144-S13\/B4D10 support 4-20 mA current signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. While natively a voltage input module (1-5V), you can measure 4-20 mA current loops by installing a precision 250-ohm shunt resistor across the terminal inputs to convert the current into the required voltage signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary benefit of the \/B4D10 terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/B4D10 option provides a dual-redundant pressure clamp interface. This allows you to wire field devices in a redundant configuration directly to the module, ensuring continuous data acquisition even during a single-path wiring failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the SDV144-S13 compatible with legacy CS 3000 systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. As part of the Yokogawa FIO family, the SDV144-S13 maintains backward compatibility with CENTUM CS 3000 systems while being fully optimized for the latest CENTUM VP and ProSafe-RS platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the 12-bit resolution impact signal accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 12-bit A\/D conversion provides 4,096 discrete levels across the signal range. Combined with ±0.1% FS accuracy, this ensures the control system receives precise measurements suitable for high-accuracy process monitoring and safety functions.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43155448660058,"sku":"SDV144-S13\/B4D10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/88._1e5e8793-50e4-4f56-9d66-69f65ea2f85f.jpg?v=1774925419","url":"https:\/\/www.spareoil.com\/products\/analog-input-brand-new-original-yokogawa-sdv144-s13-b4d10","provider":"SpareOil Automation","version":"1.0","type":"link"}