{"product_id":"analog-input-module-0-5-vdc-yokogawa-f3ad04-5v-fa-m3","title":"Analog Input Module 0-5 VDC | Yokogawa F3AD04-5V FA-M3","description":"\u003ch2\u003eYokogawa F3AD04-5V FA-M3 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed voltage signal acquisition in Yokogawa FA-M3 PLC platforms, the \u003cstrong\u003eYokogawa F3AD04-5V\/CT\u003c\/strong\u003e (\u003cstrong\u003eF3AD04-5V\u003c\/strong\u003e Analog Input Module) provides direct physical signal conversion into digital values for backplane processing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3AD04-5V\u003c\/strong\u003e: Base hardware designation for the 4-channel analog voltage input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/CT\u003c\/strong\u003e: Factory suffix indicating conformal coating option for extended environmental protection against atmospheric contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3AD04-5V\/CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 W x 100 H x 83.2 D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC from backplane (~80 mA current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e4 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Cycle\u003c\/td\u003e\n\u003ctd\u003e1 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation between field channels and internal system circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Channel-to-System Isolation and Processing\u003c\/h3\u003e\n\u003cp\u003eThe F3AD04-5V incorporates dedicated photocoupler isolation barriers between field-side terminal wiring and the internal FA-M3 backplane bus. This electrical separation prevents ground loop currents and field-induced common-mode voltage spikes from degrading backplane communications. The module continuously executes 12-bit A\/D conversion cycles across all 4 channels at a deterministic rate of 1 ms per channel, ensuring high-frequency signal fidelity for closed-loop control algorithms without overloading system backplane bus bandwidth.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F3AD04-5V module support hot-swapping while the FA-M3 base rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: No, field engineers must remove system power from the FA-M3 rack before removing or inserting the F3AD04-5V module to prevent arc flashes, backplane connector damage, or module logic corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle field-side overvoltage conditions?\u003c\/p\u003e\n\u003cp\u003eA: The input circuitry incorporates built-in overvoltage protection and onboard self-diagnostic routines that report fault conditions directly to the FA-M3 CPU via system error registers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the F3AD04-5V securely into the designated FA-M3 rack slot until the module lock engages firmly. Run all analog input signal lines using twisted-pair shielded cabling, keeping signal wiring strictly separated from high-voltage AC lines and motor drive outputs to prevent inductive cross-talk. Terminate cable shields to the designated system ground point at one end only to prevent ground loop formation. Maintain standard 5-thread engagement when tightening terminal connections, and verify ambient cabinet airflow to ensure operating temperatures stay strictly within the 0 to 55 deg C specification.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43882067787866,"sku":"F3AD04-5V","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/843_615af821-c0a0-4b46-aca6-2164de88f5f2.jpg?v=1787281873","url":"https:\/\/www.spareoil.com\/products\/analog-input-module-0-5-vdc-yokogawa-f3ad04-5v-fa-m3","provider":"SpareOil Automation","version":"1.0","type":"link"}