{"product_id":"anr10d-423-s1-yokogawa-centum-cs-vp-node-interface-units","title":"ANR10D-423 S1 Yokogawa CENTUM CS\/VP Node Interface Units","description":"\u003ch2\u003eYokogawa ANR10D-423 S1 Node Interface Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed data transfer and fault-tolerant connectivity in Yokogawa FIO and CENTUM CS\/VP systems, the \u003cstrong\u003eYokogawa ANR10D-423 S1\u003c\/strong\u003e (\u003cstrong\u003eANR10D\u003c\/strong\u003e Node Interface Unit) provides direct physical\/electrical execution. It serves as an interface between centralized control platforms and distributed I\/O clusters while operating over a dual-redundant ER Bus architecture. The unit digitizes 4-20 mA DC and 1-5 V DC analog field signals via integrated multi-channel conversion logic, passing structured process variables to the system backplane across isolated signal paths.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Structural Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANR10D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eBase Node Interface Unit \/ Bus Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply module interface configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC ambient line voltage power rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack-mount chassis profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eS1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStyle code S1 hardware revision level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANR10D-423 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e480.0 mm x 180.0 mm x 450.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA \/ 120 W (220-240 V AC), 200 VA \/ 120 W (100-120 V AC), 5.5 A (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ER Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Standard\u003c\/td\u003e\n\u003ctd\u003e19-inch rack-mount enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Signal Inputs\u003c\/td\u003e\n\u003ctd\u003e16 channels, configurable for 4-20 mA DC \/ 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conversion Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohm (current mode), \u0026gt;1 MOhm (voltage mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation \u0026amp; CJC Architecture\u003c\/h3\u003e\n\u003cp\u003eThe ANR10D-423 S1 utilizes galvanically isolated input pathways across individual channels to block common-mode noise and prevent ground potential differentials from disturbing system logic. The internal analog-to-digital processing circuitry routes field signals through high-impedance input stages that maintain signal integrity along the 4-20 mA HART loop protocol. Designed for continuous process monitoring, the module executes channel-to-channel isolation while maintaining internal cold junction compensation (CJC) stability during ambient temperature fluctuations within control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the ANR10D-423 S1 handle communication link failures on the bus? A: The module relies on a dual-redundant ER Bus connection. If a physical break or signal degradation occurs on the primary bus line, internal switching logic redirects transmission to the secondary line without interrupting data acquisition.\u003c\/p\u003e\n\u003cp\u003eQ: What power options are supported by the ANR10D-423 S1 base assembly? A: The assembly accommodates 100-120 V AC (200 VA \/ 120 W load), 220-240 V AC (230 VA \/ 120 W load), or direct 24 V DC power feeds operating up to 5.5 A.\u003c\/p\u003e\n\u003cp\u003eQ: Can signal lines be routed directly to the unit without external isolation barriers? A: The onboard channel-to-channel and channel-to-system galvanic isolation protects system backplane electronics from field-side voltage spikes, though external intrinsic safety (Ex i) barriers remain necessary when interfacing with hazardous field areas.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the ANR10D-423 S1 horizontally within a standard 19-inch marshalling rack, verifying that side clearance allows unimpeded vertical airflow across the chassis housing. Ground the chassis frame directly to the cabinet main earth bar using a low-impedance copper conductor. Route primary and secondary ER Bus cabling through dedicated wire raceways separated from high-voltage AC utility wiring to suppress inductive cross-talk. Terminate all 4-20 mA current loop cable shields at one single point on the cabinet earth bus to avoid ground loops. Ensure all system rack mounting screws are tightened uniformly to maintain stable chassis ground bonding.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43917049200730,"sku":"ANR10D-423 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/428.1_ded9eea6-2054-4ae1-9179-05a1f43bf9b1.jpg?v=1787792440","url":"https:\/\/www.spareoil.com\/products\/anr10d-423-s1-yokogawa-centum-cs-vp-node-interface-units","provider":"SpareOil Automation","version":"1.0","type":"link"}