{"product_id":"bently-nevada-125768-01-rs232-rs422-serial-communication-module","title":"Bently Nevada 125768-01 RS232\/RS422 Serial Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 125768-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the essential communication backbone for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/20 Rack Interface Module (RIM)\u003c\/strong\u003e. This I\/O module establishes the physical link between the 3500 Machinery Protection System and external automation platforms. By providing dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS232 and RS422\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserial interfaces, it enables the seamless export of static data, dynamic waveforms, and alarm statuses to DCS, PLC, or System 1 software. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% New and Original\u003c\/strong\u003e, ensuring high-speed, error-free data transmission in mission-critical environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125768-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAssociated Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/20 Rack Interface Module (RIM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x RS232 (DB9) and 1 x RS422 (9-pin terminal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU (Serial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to +185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% non-condensing relative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e242 mm x 112 mm x 25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA, ATEX, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Efficiency Data Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 125768-01 supports Modbus RTU, allowing third-party control systems to poll machinery health data directly. This removes the need for complex intermediate gateways and simplifies system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Interface Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith both RS232 and RS422 ports, the module accommodates various distance requirements. Use the RS232 port for local configuration or the RS422 interface for long-distance communication (up to 1.2km) to a centralized control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImmunity to Industrial Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada engineers this module to thrive in high EMI environments. The internal circuitry filters out electrical interference from variable frequency drives (VFDs) and heavy motors, preserving the integrity of critical alarm signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Temperature Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard commercial communication cards, the 125768-01 operates reliably at temperatures up to +85°C. This makes it suitable for non-air-conditioned field enclosures near turbines or steam-driven equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlacement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the 125768-01 into the rear of the 3500 rack, specifically in the slot directly behind the 3500\/20 Rack Interface Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor RS422 long-distance runs, ensure you apply proper termination resistors (typically 120 ohms) at the end of the communication loop to prevent signal reflection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize shielded twisted-pair cabling for all serial connections. Connect the shield to the rack ground to eliminate common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the RS232 and RS422 ports simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 125768-01 provides both ports for hardware flexibility. However, communication typically occurs through one active protocol path at a time to the host 3500\/20 RIM. Check your rack configuration software to define the primary data path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module draws its required 24V DC power directly from the 3500 rack backplane via the connection to the 3500\/20 RIM. This ensures that communication stays online as long as the rack power supply is active.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 125768-01 support \"System 1\" software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module acts as the physical gateway for the 3500\/20 RIM to stream high-resolution data to the System 1 diagnostic platform. It handles the high-speed transfer of buffered signals required for detailed machinery vibration analysis and transient data collection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 125768-01 compatible with older 3500\/20 RIMs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 125768-01 is the standard serial I\/O module for the 3500\/20 series. If you are upgrading from an older serial interface, this module serves as a direct, drop-in replacement to restore Modbus or diagnostic connectivity.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870885253210,"sku":"3500\/22 125768-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/376.jpg?v=1776764696","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-125768-01-rs232-rs422-serial-communication-module","provider":"SpareOil Automation","version":"1.0","type":"link"}