{"product_id":"bently-nevada-133292-01-low-voltage-dc-power-supply-module","title":"Bently Nevada 133292-01 Low Voltage DC Power Supply Module","description":"\u003ch2\u003eBently Nevada 133292-01 3500 Series Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 133292-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/15\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for low-voltage DC power regulation within 3500 Monitoring Systems. This hardware component interfaces incoming 24 VDC external lines via the 133300-01 I\/O module to drive multi-rail stabilized output current directly across the internal rack backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e133292-01 (Part of 3500\/15-07-07-05 assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard 3500 slot allocation weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eFull-height single-slot 3500 rack format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput range 20 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Module P\/N\u003c\/td\u003e\n\u003ctd\u003e133292-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput I\/O Module P\/N\u003c\/td\u003e\n\u003ctd\u003e133300-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003eRegulated multi-rail backplane distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eFront-panel LEDs for Power Supply OK and Module OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003eUp to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Monitoring \u0026amp; TSI Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe power module architecture incorporates active cross-talk suppression circuitry to prevent line-side voltage transients from introducing high-frequency noise into adjacent machinery protection channels. By maintaining stable, isolation-filtered multi-rail DC outputs, the unit preserves the precision calibration profiles required for eddy-current probe scaling across proximity measurement loops. This stable power rail distribution allows attached monitor cards to execute gap voltage validation routines, maintaining accurate -10 VDC targets for steady-state displacement signals and cross-axis tracking during dynamic rotor dynamics analysis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the power supply subsystem handle online hot-swap procedures during active operations?\u003c\/p\u003e\n\u003cp\u003eA: Technicians change out a faulty active module without system downtime only if the 3500 rack utilizes a redundant dual-supply configuration. When a single module is removed, the parallel supply automatically maintains the entire backplane current load without phase or voltage dropouts.\u003c\/p\u003e\n\u003cp\u003eQ: What input protection does the 133300-01 low-voltage DC input I\/O module provide?\u003c\/p\u003e\n\u003cp\u003eA: The input I\/O module incorporates transient voltage surge suppression barriers and reverse-polarity diode protection circuits to isolate internal backplane logic from upstream DC battery bus disturbances.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the 133292-01 active power supply module into the leftmost designated power slots of the 3500 chassis, slide it smoothly along the chassis guides, and tighten the front panel screws.\u003c\/li\u003e\n\u003cli\u003eFasten the matching 133300-01 input I\/O module directly onto the rear chassis backplane connectors corresponding to the slot position of the front power module.\u003c\/li\u003e\n\u003cli\u003eConnect the nominal 24 VDC power source using minimum 14 AWG stranded copper wire, maintaining tight screw terminal connections to prevent contact resistance heating.\u003c\/li\u003e\n\u003cli\u003eRoute input DC source lines apart from dynamic transducer cable paths within the cabinet layout to prevent any potential electromotive noise coupling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870886400090,"sku":"3500\/15-07-07-05(133292-01+133300-01)","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/169_2c6756d0-5003-402d-b508-4b0153cea1ef.jpg?v=1772678733","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-133292-01-low-voltage-dc-power-supply-module","provider":"SpareOil Automation","version":"1.0","type":"link"}