{"product_id":"bently-nevada-330101-00-16-10-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-16-10-02-00 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eConfigured for displacement measurement in rotating machinery, the \u003cstrong\u003eBently Nevada 330101-00-16-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330101\u003c\/strong\u003e 8 mm Proximity Probe) provides direct physical execution of gap-to-voltage conversion for vibration and position monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-16-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 mm tip diameter, 160 mm case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven by 3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximity Probe Type\u003c\/td\u003e\n\u003ctd\u003e8 mm 3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal System Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProximity Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330101 probe system requires precise calibration to the target material to maintain the industry-standard scale factor of 7.87 V\/mm (200 mV\/mil). During installation, the gap voltage must be validated against a -10 VDC target at the probe midpoint to ensure linear response within the 0.25 mm to 2.3 mm linear range. Proper rotor dynamics analysis depends on minimizing cross-talk between adjacent probes; ensure probe spacing exceeds minimum requirements to prevent electromagnetic interference. Shielded coaxial cables must be routed in grounded conduits to mitigate signal noise in high-EMI environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the purpose of the ClickLoc connector on this probe?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector is designed to provide a secure, vibration-resistant connection while ensuring consistent contact pressure for the coaxial signal path, minimizing impedance discontinuities.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be used with non-3300 XL Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003eA: No. The 330101 probe is calibrated specifically for the 3300 XL Proximitor sensor internal circuit impedance. Using it with legacy 3300 or 7200 series sensors will result in incorrect voltage output and loss of linear calibration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the probe mounting bracket is rigid to avoid resonance within the machine's operating frequency range.\u003c\/li\u003e\n\u003cli\u003eVerify that the probe tip is installed perpendicular to the target surface. Misalignment exceeding 5 degrees can degrade the linearity of the gap-to-voltage transfer function.\u003c\/li\u003e\n\u003cli\u003eApply standard thread-locking compound to the jam nuts once the gap distance is set to prevent loosening due to machine vibration.\u003c\/li\u003e\n\u003cli\u003eEnsure the coaxial cable connector remains dry and free of contaminants. The ClickLoc connector should be engaged until an audible or tactile click confirms proper seating.\u003c\/li\u003e\n\u003cli\u003eGround the probe case through the mounting assembly if required by specific plant loop-grounding standards, noting that the Proximitor sensor typically establishes the common signal ground.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43568918593626,"sku":"330101-00-16-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330101-00-16-10-02-00.png?v=1782703959","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-330101-00-16-10-02-00-3300-xl-8-mm-proximity-probe","provider":"SpareOil Automation","version":"1.0","type":"link"}