{"product_id":"bently-nevada-330101-00-79-15-02-05-3300-xl-8-mm-proximity-probes","title":"Bently Nevada 330101-00-79-15-02-05 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in rotating machinery, the \u003cstrong\u003eBently Nevada 330101-00-79-15-02-05\u003c\/strong\u003e (\u003cstrong\u003e330101\u003c\/strong\u003e 8 mm Proximity Probe) provides direct physical signal execution via an eddy-current induction circuit.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eUnthreaded length: 0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003ctd\u003eOverall case length: 7.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eTotal length: 1.5 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eAgency approval: CSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-79-15-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.9 in case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered by Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303\/304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330101 series utilizes an eddy-current principle to detect the proximity of a conductive target. Proper scaling is required to maintain the standard 7.87 V\/mm (200 mV\/mil) output sensitivity provided by the matching 3300 XL Proximitor sensor. During installation, the gap voltage must be validated against a -10 VDC target at the mid-linear range to ensure linear response. Signal integrity depends on minimizing cross-talk between adjacent probes and ensuring the target material surface conforms to Bently Nevada material correction specifications to maintain accurate rotor dynamic vibration data.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330101 probe be utilized with legacy 3300 Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003eA: The 330101 8 mm probe is calibrated for the 3300 XL system. While physically compatible with legacy 3300 (non-XL) systems, the Proximitor sensor must be recalibrated to maintain the system's 200 mV\/mil sensitivity.\u003c\/p\u003e\n\u003cp\u003eQ: What are the requirements for the ClickLoc connector during assembly?\u003c\/p\u003e\n\u003cp\u003eA: The Miniature coaxial ClickLoc connector must be fully seated and kept free of contaminants to prevent impedance fluctuations in the 50 ohm coaxial circuit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the probe mounting bracket is rigid to minimize resonance effects at the probe location.\u003c\/li\u003e\n\u003cli\u003eVerify that the total system length (probe plus extension cable) matches the Proximitor sensor calibration (5 m or 9 m).\u003c\/li\u003e\n\u003cli\u003eUse the provided locknut to secure the probe position; ensure the locknut is tightened to prevent loosening due to machine-induced vibration.\u003c\/li\u003e\n\u003cli\u003ePerform a bench-top gap verification using a calibrated micrometer to confirm the -10 VDC setpoint before full installation into the machinery casing.\u003c\/li\u003e\n\u003cli\u003eEnsure the cable is not subjected to sharp bends or mechanical tension during routing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43569442586714,"sku":"330101-00-79-15-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330101-00-24-10-02-05_7c046a92-cf1f-41a6-a52e-dbce36238d9c.png?v=1782713703","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-330101-00-79-15-02-05-3300-xl-8-mm-proximity-probes","provider":"SpareOil Automation","version":"1.0","type":"link"}