{"product_id":"bently-nevada-330130-045-02-00-3300-xl-series-extension-cable","title":"Bently Nevada 330130-045-02-00 3300 XL Series Extension Cable","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330130-045-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330130\u003c\/strong\u003e Extension Cable, operates as a dedicated hardware component for RF signal transmission within 3300 XL Proximitor Sensor networks. It serves as the calibrated electrical pathway linking a proximity probe to a remote transducer module, ensuring continuous analog loop transmission without introducing uncompensated impedance mismatches or signal phase errors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330130\u003c\/strong\u003e - Base Model: 3300 XL Standard Extension Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-045\u003c\/strong\u003e - Cable Length Option: 4.5 metres (14.8 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e - Connector Protector and Cable Option: Standard cable with connector protectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e - Agency Approval Option: Not required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-045-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 m physical length (75 ohm coaxial geometry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.0 W (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer System Matching\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5 mm and 8 mm Proximity Transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe physical geometry of the 330130-045-02-00 extension cable maintains tight impedance tolerances over its 4.5 m path to stabilize eddy-current probe scaling for proximity measurement systems. This coaxial engineering preserves the fidelity of high-frequency RF signals against industrial interference, allowing accurate gap voltage validation targeting standard -10 VDC operational baselines. Effective cross-talk suppression prevents voltage distortions when parallel cables are run within proximity of machinery rotor systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the technical purpose of the integrated connector protectors (-02 suffix) on this standard cable?\u003c\/p\u003e\n\u003cp\u003eA: The connector protectors provide a physical environmental seal over the coaxial connections, preventing moisture ingress and eliminating accidental grounding loops caused by bare metal connectors touching structural conduits or machinery casings.\u003c\/p\u003e\n\u003cp\u003eQ: Will trimming excess length off this 4.5 m cable during installation affect the transducer loop?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Trimming changes the absolute electrical length and total capacitance of the coaxial line. The remote Proximitor sensor is factory-calibrated for an exact total system length (typically 5.0 m or 9.0 m including probe); altering this length invalidates the linear scale factor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the cumulative electrical length of the proximity probe and extension cable matches the specific configuration of the Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the minimum static bend radius of 25.4 mm during cable placement to prevent damage to the internal dielectric core.\u003c\/li\u003e\n\u003cli\u003eEnsure the connector protectors are fully seated and locked over the coaxial joint to maintain physical and environmental isolation.\u003c\/li\u003e\n\u003cli\u003eRoute the non-armored extension cable within grounded metal conduits or dedicated low-voltage instrumentation channels to maintain maximum cross-talk suppression.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43650211119194,"sku":"330130-045-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330130-040-00-00_44c16977-be72-4a53-8c42-df71a6ffb05a.png?v=1783928768","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-330130-045-02-00-3300-xl-series-extension-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}