{"product_id":"bently-nevada-330130-080-00-cn-3300-xl-series-extension-cable","title":"Bently Nevada 330130-080-00-CN 3300 XL Series Extension Cable","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330130-080-00-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330130\u003c\/strong\u003e Extension Cable, operates as a dedicated hardware component for RF signal transmission within 3300 XL Proximitor Sensor networks. It functions as the calibrated low-attenuation physical pathway linking a proximity probe to a remote transducer module, maintaining consistent capacitance parameters to prevent analog measurement loop distortion.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330130\u003c\/strong\u003e - Base Model: 3300 XL Standard Extension Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-080\u003c\/strong\u003e - Cable Length Option: 8.0 metres (26.2 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e - Connector Protector and Cable Option: Standard cable (non-armored)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e - Agency Approval Option: Country-specific approvals (China)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-080-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.272 kg net (Shipping weight 3.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.0 m nominal cable length (75 ohm triaxial geometry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.0 W (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003eFluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe physical geometry and integrated FEP insulation layers of the 330130-080-00-CN extension cable are designed to stabilize overall eddy-current probe scaling across the 8.0 m transmission length. By controlling internal capacitive and inductive parameters, the cable mitigates high-frequency signal degradation during continuous rotor dynamics monitoring. This electrical consistency enables precise gap voltage validation back to target -10 VDC operational baselines, ensuring stable signal integrity at the remote Proximitor interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does modifying the physical length of the 330130-080-00-CN cable impact system performance?\u003c\/p\u003e\n\u003cp\u003eA: Trimming or splicing this cable alters its total nominal capacitance and electrical length. Because the Proximitor sensor relies on a tuned 5.0 m or 9.0 m total circuit loop, changing the length shifts the calibrated linear scale factor and invalidates displacement readouts.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation restrictions regarding the standard non-armored (-00) option?\u003c\/p\u003e\n\u003cp\u003eA: The non-armored option lacks native resistance to external mechanical compression or abrasions. When routed across exposed infrastructure or high-vibration zones, it must be run inside a grounded metallic conduit to preserve the structural uniformity of the triaxial core.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the combined physical length of the extension cable and the target proximity probe matches the fixed 5.0 m or 9.0 m configuration specified on the Proximitor label.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum static bend radius of 25.4 mm during layout execution to prevent permanent structural deformation of the inner dielectric and shielding layers.\u003c\/li\u003e\n\u003cli\u003eCover all subminiature coaxial connector joints using insulation sleeves or specialized self-fusing tape to prevent ground loops caused by physical contact with adjacent structures.\u003c\/li\u003e\n\u003cli\u003eRun non-armored transducer cabling through dedicated low-voltage instrumentation channels to minimize noise from adjacent power distribution links.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43650603876442,"sku":"330130-080-00-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330130-070-00-05_0bc4773a-3682-4bee-a9bc-4b79ba284f90.png?v=1783929398","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-330130-080-00-cn-3300-xl-series-extension-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}