{"product_id":"bently-nevada-3500-05-02-04-01-00-01-7-slot-system-rack","title":"Bently Nevada 3500\/05-02-04-01-00-01 7-Slot System Rack","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/05-02-04-01-00-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the central structural frame and electrical nerve center for the 3500 Machinery Protection System. This 12-inch Mini-Rack provides seven dedicated module slots, housing the critical monitors, power supplies, and transient data interfaces (TDI) required for rotating machinery oversight. It facilitates high-speed data exchange across the backplane while distributing redundant power to ensure continuous operation of vibration, position, and temperature sensors.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/05-02-04-01-00-01 configuration follows a specific engineering logic:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Rack Size):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12-inch Mini-Rack with 7 available slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04 (Mounting Options):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel Mount (installs internally to a cabinet or flat surface).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Agency Approval Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSA-C-US (North American Safety Standards).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Reserved):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (European Compliance):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes CE Mark for European market entry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/05-02-04-01-00-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRack Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-inch Mini-Rack (7 Module Slots)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnti-corrosion coated cold-rolled steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Connectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated for oxidation resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +149 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to +185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Bus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed digital bus with redundant traces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis 12-inch variant solves the challenge of limited cabinet space. It provides a full-feature monitoring solution for smaller machinery trains without the unnecessary bulk of a standard 19-inch rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe backplane incorporates redundant power traces. This design prevents a single power supply failure from interrupting the monitoring of critical assets, maintaining system uptime in mission-critical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGold-plated backplane connectors eliminate the risk of oxidation in humid or corrosive industrial atmospheres. This ensures stable, low-impedance electrical contact over long-term deployments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Thermal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe industrial-grade steel chassis and high-spec components withstand extreme temperature swings (-30 °C to +65 °C), making it suitable for remote field enclosures or high-heat plant environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe panel-mount design allows for direct bolting to internal cabinet plates. This eliminates the need for complex rack rails and provides a high-vibration resistant mounting solution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Can I use 19-inch rack modules in this 12-inch Mini-Rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3500\/05 Mini-Rack uses the same universal slot dimensions and backplane architecture as the standard 19-inch rack. It accepts all standard 3500 series monitors and interfaces; only the total number of available slots (7 vs 14) differs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Does the panel-mount option include a faceplate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe panel-mount configuration (Option 04) is designed for internal cabinet installation where the rack attaches directly to a mounting plate. For external-facing applications, a different mounting option (Rack Mount) would be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Is this 3500\/05-02-04-01-00-01 unit original Bently Nevada stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment from Bently Nevada. It arrives in the original factory packaging with all relevant serial numbers and technical documentation intact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. How does the backplane handle communication with the control system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe backplane routes all monitor data to the TDI (Transient Data Interface) or RIM (Rack Interface Module), which then transmits the processed vibration and status information to your DCS or PLC via Ethernet or serial communication protocols.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42895037038682,"sku":"3500\/05-02-04-01-00-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/58.jpg?v=1770371202","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-3500-05-02-04-01-00-01-7-slot-system-rack","provider":"SpareOil Automation","version":"1.0","type":"link"}