{"product_id":"bently-nevada-990-vibration-transmitter-990-04-50-01-00","title":"Bently Nevada 990 Vibration Transmitter | 990-04-50-01-00","description":"\u003cp\u003eConfigured for proximity probe signal conditioning and 4-20 mA current loop conversion in machinery protection networks, the \u003cstrong\u003eBently Nevada 990-04-50-01-00\u003c\/strong\u003e (\u003cstrong\u003e990\u003c\/strong\u003e Vibration Transmitter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e2-Wire Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e0-4 mils pp (0-100 um pp) displacement amplitude range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet) total calibrated system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips pre-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eNo hazardous area agency approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-04-50-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Device\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e0-4 mils pp (0-100 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eProportional 4-20 mA loop current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1000 ohm including cable at 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 VDC input at the transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard 990 transmitter rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered via +12 to +35 VDC supply line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC Targets) \u0026amp; Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe module conditions raw eddy-current signal inputs generated by a 3300 NSv proximity probe across a tuned 5.0-metre system length. Installation protocol mandates gap voltage validation at the raw signal monitoring terminals to ensure a static baseline target of -10 VDC at mid-span. Internal filtering and shielded termination maintain cross-talk suppression and signal integrity when multiple transmitters are mounted adjacent to one another along shared cabinet DIN rails.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum permissible loop impedance for this transmitter at maximum voltage?\u003c\/p\u003e\n\u003cp\u003eA: At an operating voltage of 35 VDC, the total loop resistance limit is 1000 ohm, including all interconnecting field cabling resistance.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal circuit handle over-range loop conditions?\u003c\/p\u003e\n\u003cp\u003eA: The transmitter incorporates an internal current limiting circuit set to a typical threshold of 23 mA to protect downstream loop monitoring cards during over-range vibration events.\u003c\/p\u003e\n\u003cp\u003eQ: What power input range must be supplied to the field connection terminals?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an external power supply delivering between +12 VDC and +35 VDC directly across the transmitter terminals to drive the 4-20 mA measurement loop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transmitter module directly onto a grounded 35 mm DIN rail, verifying mechanical lock engagement.\u003c\/li\u003e\n\u003cli\u003eConnect the 3300 NSv proximity probe extension cable coaxial connector to the transmitter input interface, securing hand-tight.\u003c\/li\u003e\n\u003cli\u003eValidate static DC gap voltage using a multimeter connected to the test terminals, adjusting probe insertion depth to achieve -10 VDC.\u003c\/li\u003e\n\u003cli\u003eConnect 2-wire shielded cable from the control system 24 VDC analog input terminals to the transmitter power\/output connections.\u003c\/li\u003e\n\u003cli\u003eTerminate the field cable shield to the cabinet earth bus bar at a single point to mitigate ground loops and electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43825042292826,"sku":"990-04-50-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/990-05-70-01-011_0abe59f2-1b54-4c6d-915c-28818db72f1d.png?v=1786436067","url":"https:\/\/www.spareoil.com\/products\/bently-nevada-990-vibration-transmitter-990-04-50-01-00","provider":"SpareOil Automation","version":"1.0","type":"link"}