{"product_id":"bmxami0800-schneider-modicon-x80-analog-input-module-8-channel","title":"BMXAMI0800 Schneider Modicon X80 Analog Input Module 8 Channel","description":"\u003ch2\u003eSchneider BMXAMI0800 Modicon X80 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider BMXAMI0800\u003c\/strong\u003e, serves as the primary \u003cstrong\u003eBMXAMI0800\u003c\/strong\u003e Analog Input Module utilized to execute high-precision data acquisition across Modicon M340 and M580 Programmable Automation Controller (PAC) networks. The hardware channels 8 non-isolated, high-level analog current or voltage signals directly into the processing core over the common Modicon X80 backplane. Operating with a 15-bit plus sign internal resolution, the unit converts raw industrial sensor inputs into structured digital images while executing integrated first-order digital filtering. Status indication LEDs provide immediate diagnostic feedback for localized loop faults, backplane communication integrity, and channel-level operational states.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMXAMI0800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module (Non-isolated, High-level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Platforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M340, Modicon M580 (Local or Remote I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Analog Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V, +\/- 5 V, 0-10 V, 0-5 V, 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Input Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 20 mA, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign (16-bit conversion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ (Voltage Mode), 250 Ω (Current Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Voltage: \u0026lt;= 0.1% full scale; Direct Current: \u0026lt;= 0.3% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycle Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast Read: 1 ms + 1 ms x active channels; Nominal Read: 9 ms for 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 30 V (Voltage), +\/- 30 mA (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1400 V DC between channel-to-ground and channel-to-bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.04 W at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 RUN LED (Green), 1 ERR LED (Red), 1 I\/O LED (Red), 8 Channel LEDs (Green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28-way terminal connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 with conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF Reliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 700 000 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m nominal; 2000 to 5000 m with derating factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 100 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe BMXAMI0800 leverages the high-speed bus communication velocity inherent to the Modicon X80 platform. The module interfaces directly with the parallel backplane, which handles deterministic cyclical data transfers to the primary PAC processor. Because the 8 analog channels share a common reference point without channel-to-channel isolation, the module maximizes I\/O density scaling within a compact 32 mm chassis footprint. The backplane bus executes synchronous transfers, matching the module conversion cycle time of 9 ms for all 8 channels in nominal mode. Furthermore, firmware flash compatibility embedded within the X80 platform ensures that the BMXAMI0800 retains precise calibration data and conversion coefficients during system-wide firmware updates, maintaining consistency across remote and local drop topographies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BMXAMI0800 support electrical isolation between individual input channels?\u003c\/p\u003e\n\u003cp\u003eA: No. The module does not provide channel-to-channel isolation. All 8 analog input loops share a common internal reference ground. However, galvanic isolation of 1400 V DC exists between the total channel group and the internal backplane bus, as well as between the channel group and protective earth ground.\u003c\/p\u003e\n\u003cp\u003eQ: How does operating altitude above 2000 meters impact the hardware?\u003c\/p\u003e\n\u003cp\u003eA: The module operates at 100% capacity from 0 to 2000 m. For deployments between 2000 m and 5000 m, you must apply an environmental derating factor. This derating addresses the reduced thermal dissipation efficiency of rarer air to prevent internal component overheating.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current and voltage limits the inputs can withstand before risking physical damage?\u003c\/p\u003e\n\u003cp\u003eA: The hardware incorporates continuous overload protection circuits on its analog fronts. The voltage inputs tolerate a maximum sustained overload of +\/- 30 V, and the current loops tolerate up to +\/- 30 mA before risking damage to the internal 250 Ω precision shunt resistors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Connection:\u003c\/strong\u003e Utilize the dedicated 28-way connector block for all field-side wiring. Ensure conductors are properly stripped and crimped with ferrules to maintain persistent physical contact and eliminate parasitic resistance in 4-20 mA loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Standards:\u003c\/strong\u003e Terminate the braided shields of all incoming analog signal cables directly to the grounding bar of the enclosure or the X80 rack grounding terminal. Do not connect the shield at the sensor side if it is already grounded at the rack side, preventing hazardous ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrosstalk and Noise Mitigation:\u003c\/strong\u003e Because this module features non-isolated channels, group signals with similar voltage potentials together. Route low-voltage analog signal cables through dedicated, isolated wire ways separated from high-voltage AC motor lines and switching inductive loads to prevent electromagnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Retention:\u003c\/strong\u003e Align the module with the slot guides of the Modicon X80 rack, press firmly until the rear connector seats into the backplane bus, and tighten the top retention screw to secure the module against low-frequency industrial vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43529695264858,"sku":"BMXAMI0800","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/201.1_37084083-f68d-4098-a70b-7ead0ce26fd9.jpg?v=1782115909","url":"https:\/\/www.spareoil.com\/products\/bmxami0800-schneider-modicon-x80-analog-input-module-8-channel","provider":"SpareOil Automation","version":"1.0","type":"link"}